Error with simout = sim (...)
조회 수: 2 (최근 30일)
이전 댓글 표시
I have defined three signals with timeseries, then I want to simulate a model loading this three signals I have a error with the function simout = sim ('model', 'LoadExternalInput','on', 'ExternalInput','inp', 'ExternalInput','inp1','ExternalInput','inp2'); Error using model (line 41) The number of external inputs must be equal to the number of root-level input port blocks. Root-level input port blocks include Trigger and Enable blocks. The model contains 3 root-level input port blocks, but 1 external inputs were specified in Configuration Parameters -> Data Import/Export -> Input. I don't know why doesn't recognize the signals
댓글 수: 0
답변 (1개)
nick
2024년 10월 3일
Hi Tania,
The error is due to the way format of specifying external inputs for Simulink model. In MATLAB R2016, you can specify multiple external inputs as a single concatenated variable, as shown:
inputData = [timeVector, inp.Data, inp1.Data, inp2.Data];
simout = sim('model', 'LoadExternalInput', 'on', 'ExternalInput', 'inputData');
You can refer to 'Model Parameters' in Simulink to learn more about 'ExternalInput'. You can access the documentation using the following command in MATLAB Command window:
doc Model Parameters
댓글 수: 0
참고 항목
카테고리
Help Center 및 File Exchange에서 Prepare Model Inputs and Outputs에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!