필터 지우기
필터 지우기

Specifying discrete sample time for variable-size signals

조회 수: 76 (최근 30일)
sst
sst 2012년 2월 13일
편집: Gilmar 2013년 10월 12일
Hi, I am trying to use the inherit sample time setting (-1) for the Assignment block, using a variable-size signal as an index vector coming from an external source. I have selected the following options for the model:
Solver Type: Fixed Step Solver: discrete (no continuous states) Start time: 0.0 Stop Time: Inf Fixed-step size (fundamental sample time): 0.001s
When I try to update the model, I get the following error
The signal at input port 3 of '.../Assignment1' is a variable-size signal with a nondiscrete sample time. The sample time for any variable-size signal must be discrete
Even though I have specified this in the simulation configuration parameters section, why am I still getting this error message? The message goes away if I explicitly specify the sample time as 0.001 instead of -1. Any help would be greatly appreciated.
Running MATLAB R2010bSP1 on Windows XP SP3 (32-bit)
Thanks, Sundeep.
  댓글 수: 3
sst
sst 2012년 2월 13일
Hello TAB, the index vector is being driven by output port 2 of a 'Find Nonzero Elements' block; the nonzero input elements themselves. The find block, in turn, is being driven by a merge block, which is configured to use variable-size signals. The sample time for the find block has been specified as -1 (inherited).
sst
sst 2012년 2월 13일
Also, the merge block has the outputs of several constant blocks as its inputs. Each constant block has the default sample time of Inf. Could that be causing the problem? Is there some way to specify programmatically that the sample time should be the same as the solver fixed-step size, for example?

댓글을 달려면 로그인하십시오.

채택된 답변

sst
sst 2012년 2월 14일
Hi Kaustubha, while the variable-size signal was indeed a discrete sample time signal, the main input signal (In1) to the assignment block was not. By inserting a rate transition block, I was able to convert that continuous sample time signal to a discrete one, and make the error go away. My guess is that the error was pointing to that continuous signal. Thanks for your help though!
  댓글 수: 2
sst
sst 2012년 2월 14일
At another level in the model, certain signals were indeed being identified as continuous sample time signals for some reason. These signals were being propagated to this level. Discretizing them solved the problem.
Kaustubha Govind
Kaustubha Govind 2012년 2월 15일
Great! Thanks for posting your solution!

댓글을 달려면 로그인하십시오.

추가 답변 (1개)

Kaustubha Govind
Kaustubha Govind 2012년 2월 13일
As TAB indicates in his/her comment, it is likely that the input signal has a continuous sample time. The Assignment block inherits that sample time (-1 means inherited sample time). The solver configuration does not affect the fact that your signal is continuous.
  댓글 수: 5
Kaustubha Govind
Kaustubha Govind 2012년 2월 14일
If all sources specify -1 as sample-time, then I think it should indeed use the solver step-size as the sample-rate. Could you try turning on Format->Sample Time Colors. Then observe if there are any blocks with continuous sample time (black lines).
sst
sst 2012년 2월 14일
Hi Kaustubha, I did as you suggested. It looks like the variable size signal entering the assignment block is indeed a discrete sample time signal. Yet, the error I get says that the signal is a variable-size signal with a nondiscrete sample time. A bug then?

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Signal Import and Export에 대해 자세히 알아보기

제품

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by