No Flow in a basic hydraulic system

조회 수: 7 (최근 30일)
alarson52
alarson52 2016년 5월 16일
댓글: alarson52 2016년 6월 13일
See attached picture. I have modeled a very simple hydraulic system and pressure readings are as expected, but I am reading no flow. I've double-checked all of my parameters and nothing seems out of line. What am I missing here?
  댓글 수: 2
Mika Herranen
Mika Herranen 2016년 6월 10일
You need a 'Hydraulic flow rate source' instead of tank.
alarson52
alarson52 2016년 6월 13일
Actually, the tank is fine. Sebastian's answer is correct. The system works fine if the pressure gauge is connected in parallel.

댓글을 달려면 로그인하십시오.

채택된 답변

Sebastian Castro
Sebastian Castro 2016년 6월 11일
I think the problem is your Hydraulic Pressure Sensor is connected in series, and is acting as an infinite resistance. Flow sensors go in series; pressure sensors go in parallel.
Make sure you connect that sensor in parallel, so there is a flow path from the tank all the way through the reference.
- Sebastian