Dynamic load implementation used in phasor mode
조회 수: 10 (최근 30일)
이전 댓글 표시
Hey, This load implementation i found on example called "24-hour Simulation of a Vehicle-to-Grid (V2G) System" The model i'm trying to build is a simple synchrounus genertor driven by steam turbine. As mentioned in title i'm using phasor simulation mode. The basic problem i have with this model is that when the rotor is not in it's nominal speed (not in nominal frquency), i'm measuring wierd/wrong Active and Reactive Power for a given constant P & Q. and actuly i realy don't understand why this happend ? perhaps the resson for that is the phasor mode ?
Thanks in Advance, Dani

댓글 수: 0
답변 (1개)
Sebastian Castro
2016년 5월 11일
Exactly as you said -- phasor mode makes the assumption that your whole system is at (or near) the fundamental system frequency. The validity of results drops off as you deviate from that frequency.
If you actually need to model significant deviations from that fundamental frequency, you will have to switch to continuous or discrete simulation mode.
- Sebastian
댓글 수: 1
NN
2020년 8월 30일
Hi Sebastian,
I am working with a microgrid model and I have power inverter/converter components. When I simulate in phasor mode i get errors. I am trying to do it in phasor mode since my model is very slow with discrete mode.I understand that Simulation under phasor mode (in Simulink software), does not allow some electric element models like diodes, inverter bridge models, transistor elements (IGBT and MOSFET). How can I solve this problem? What can I substitute for these elements? How can I model for these components which can be used for phasor mode?
Or else is there any way to increase the simulation speed of discrete model
참고 항목
카테고리
Help Center 및 File Exchange에서 Switches and Breakers에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!