How to model the local restriction (2P) for a specific pressure differential? Using parameters from a thermostatic expansion valve seems to not do the trick. Any other method that can be used to appropriately size this component?
Thanks.
P.S. Any reference would be helpful.
댓글 수: 0
답변 (1개)
Yifeng Tang
2022년 7월 1일
Depending on what you mean by "a specific pressure differential":
If you just want to drop/increase the pressure, regardless of flow rate, which is quite unlikely, you can just use a pressure source with a negative pressure increase.
If you want to find the orifice area needed to achieve a certain pressure drop by a given flow, like from a data sheet, you can set up a test harness with two ends of the restriction connected to reservoirs set at the specified pressure, then watch the flowrate. Adjust the restriction area so you get the right flowrate.