errors in MATLAB/simulink while using logic analyzer
조회 수: 3 (최근 30일)
이전 댓글 표시
Hi,
I using logic analyzer in a simple design and I got some errors:
for example:
>> Logic_Anlzr_pwm1
Warning: Matching "From" for "Goto" 'pwm1/Goto24' not found
> In Logic_Anlzr_pwm1 at 5
Warning: The model 'pwm1' does not have continuous states, hence Simulink is using the
solver 'VariableStepDiscrete' instead of solver 'ode45'. You can disable this
diagnostic by explicitly specifying a discrete solver in the solver tab of the
Configuration Parameters dialog, or by setting the 'Automatic solver parameter
selection' diagnostic to 'none' in the Diagnostics tab of the Configuration Parameters
dialog
> In Logic_Anlzr_pwm1 at 5
Error using analyzeLogicFromSimulink (line 51)
All elements in the Simulink Dataset must have the same sample time.
Error in Logic_Anlzr_pwm1 (line 7)
analyzar = analyzeLogicFromSimulink(logsout_r);
I used it before in another design and it works ok.
can anyone help me to solve this problem ?
Thanks,
Henry
댓글 수: 1
Walter Roberson
2015년 12월 9일
Have you considered running the Model Advisor? http://blogs.mathworks.com/seth/2008/11/04/introduction-to-model-advisor/
답변 (1개)
Bharath Venkataraman
2015년 12월 9일
Currently, the Logic Analyzer System object can only show signals of a single rate. If the signals you are logging are different rates, you need to reconcile them into a single rate before using the Logic Analyzer. Or else, you can instantiate multiple Logic Analyzers, each for a given rate.
댓글 수: 0
참고 항목
카테고리
Help Center 및 File Exchange에서 Configure Simulation Conditions에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!