Simulink - Rate Transition
이전 댓글 표시
Hi,
I want to use Rate Transitions in my Simulink System. I am using a Fixed-Step + Discrete Solver with a discrete step-size. If I want to implement different tasks, for example, Task 1 with a sample time of 10 ms and Task 2 with a sample time of 1 ms. Does the fixed-step size in the Configuration Parameters has to be the smallest sample time, i.e. 1 ms or is it also possible to run the whole system with 10 ms and just a few calculations with the fast sample time of 1 ms?
Thank you
채택된 답변
추가 답변 (1개)
Suneesh
2011년 12월 7일
0 개 추천
The step size in configuration parameters has to be the smallest (fundamental) step size. Other blocks can have sample times that are integer multiples of the fundamental. 'Rate Transition' block is used to connect parts of the model running at different rates
카테고리
도움말 센터 및 File Exchange에서 Multicore Processor Targets에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!