Currently I'm Taking Control Techniques for PMSM (new), at Current Controller Optimization, Implement MTPA and FWC to optimize your controller. I start taking the task, from 1 to 3 all no issues, but when I take the task 4, and follow the step by step, and checked all the setting are fine, but the output not meet the requirement, checked no error log, please help,

댓글 수: 2

Kartikey
Kartikey 2026년 10월 12일
The screenshot is too zoomed out, so it is difficult to identify the exact cause. As a troubleshooting step, remove the current Vector Concatenate block and add a new one with Number of inputs set to 3. Reconnect the signals and check whether the assessment passes.
Signal Assessment appears to be connected to the V_ao output of the PWM Reference Generator. Verify this connection and the block parameters. Use the task’s Hint section to compare the expected setup with your model.
to understand port and connection of PWM, refer to the PWM Reference Generator documentation.
BEN
BEN 2026년 10월 13일
이동: Torsten 2026년 10월 13일
Hi Kartikey,
I have reconnected the overall block diagram multiple times and attempted to adjust some of the parameters. However, I am still unable to achieve the correct output. Could you please provide your guidance and advice?
I has captured the connection and parameter for your referance, may help you to do analizing.
Thank you, Ben

댓글을 달려면 로그인하십시오.

답변 (2개)

Kartikey
Kartikey 2026년 10월 14일

0 개 추천

From page 9 of the attached PDF, I noticed a possible angle-unit mismatch. The Input mechanical angle unit parameter of the Mechanical to Electrical Position block is set to Radians, so its electrical-position output is also in radians. However, the Theta units parameter of the SinCos Embedded Optimized block is set to Per-unit.
Could you try changing the Theta units parameter to Radians, rerunning the model, and submitting the task again? I think this may resolve the mismatch. Let me know whether the assessment passes after the change.

댓글 수: 1

BEN
BEN 2026년 10월 19일 12:35
Thank you very much, after changed the Theta units parameter of the SinCos Embedded Optimized block from Per-unit to Radians is work.

댓글을 달려면 로그인하십시오.

BEN
BEN 2026년 10월 19일 12:43

0 개 추천

Dear Kartikey,
I am working on the assessment that requires adding the SinCos Embedded Optimized block from the Motor Control Blockset. The instructions specify the path as: Motor Control Blockset → Controls → Math Transforms.
However, in my installed version of MATLAB/Simulink, the block only appears under: Motor Control Blockset → Math Transforms (without the 'Controls' folder).
The block itself is present and functions correctly, but the library hierarchy differs. Could you please confirm if using the block from Motor Control Blockset → Math Transforms is acceptable for the assessment, or if a specific version of the toolbox is required?
Thank you for your guidance.
Best regards, Ben

카테고리

도움말 센터 및 File Exchange에서 Control Algorithm Design에 대해 자세히 알아보기

질문:

BEN
2026년 10월 8일

답변:

BEN
2026년 10월 19일 12:43

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by