Bode plot with variable pulse generator
이전 댓글 표시
i try to get bode plot with introduce perturbation in frequency of variable pulse generator but i cant get the bode plot also not getting any error but if i give perturbation in any other parameter like the voltage it was giving the bode plot please help me to get bode with frequency variation.

답변 (1개)
Srilekha
2026년 7월 8일 7:00
0 개 추천
Hi Ponnanthiraja,
My understanding is that you are attempting to obtain a Bode plot by perturbing the frequency parameter of a Variable Pulse Generator.
Whereas frequency response estimation generally requires perturbations on continuous system inputs rather than on pulse-generator timing parameters.
I would suggest you to try the below approaches and see if this helps to solve your issue.
Apply the perturbation to a continuous input signal (such as voltage, current, duty cycle, or control input) instead of the pulse generator frequency.
Verify whether the Variable Pulse Generator frequency is supported as a linearization or frequency-response analysis input.
If the goal is to analyze how the system responds to frequency variations, consider replacing the pulse source with a sinusoidal test signal or using Simulink Control Design/Frequency Response Estimator input points that support frequency-response analysis.
Hope this helps!