Simscape Battery SoC estimation

조회 수: 21 (최근 30일)
Korebami
Korebami 2025년 11월 10일
답변: Leepakshi 2025년 11월 19일
Good day everyone,
I recently creating a relatively large battery pack using Simscape Battery Builder. I set up a simple charging and discharging cycle to test it but the SoC I'm getting from the battery pack is discharging slower than expected. I added an estimator block which is giving me SOC values that seem more reasonable. Is there something I missed in creating the battery causing the difference?
This is also affecting the battery degradation/aging since it's based of th number of cycles. I've attached the model and code I used to create the battery pack. Thank you.

채택된 답변

Leepakshi
Leepakshi 2025년 11월 19일
Hi,
The slower SoC discharge is often due to how the battery pack calculates SoC versus the estimator. First, check the terminal voltage vs. open-circuit voltage (OCV)—terminal voltage includes the drop from internal resistance under load. If you need accurate charging behavior, use a CC-CV block for constant voltage charging. Also, review initial conditions: setting both initial SoC and initial voltage with high priority can cause conflicts, define only one.
This mathworks documentation for battery creation can help:
Thanks!

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Propulsion and Power Systems에 대해 자세히 알아보기

Community Treasure Hunt