TI Radar Toolbox with DCA1000EVM Connection - Continuous error occurs when attempting to connect with an Ethernet cable

조회 수: 5 (최근 30일)
I failed to connect to the DCA1000EVM in the TI Radar Toolbox.
This is our hardware setting
we are using awr1642boost with dca1000evm capture board
I have provided a screenshot of the device manager and Ethernet IP adress. All networks except for Ethernet have been disconnected.
This is the result of the 'ipconfig' command in CMD
This is the inbound and outbound rule configuration.
How can we solve this error??

답변 (1개)

Walter Roberson
Walter Roberson 2024년 11월 29일
편집: Walter Roberson 2024년 11월 30일
Your ipconfig shows that you have configured the local IP address of the second interface as 192.168.33.30 . However, 192.168.33.30 needs to be the address of the connected device, not the local address of the second interface. You need to configre the second interface address as something else in the 192.168.33.x range (excluding 192.168.33.255). It is probably best to configure the second interface to be 192.168.33.1
  댓글 수: 4
정빈
정빈 2024년 12월 4일
I wanted to take a moment to sincerely thank you for your help and support. Your guidance has been invaluable, and I truly appreciate the time and effort you've invested in assisting me. I am very grateful for your generosity and expertise.
Thank you again for everything. It means a lot to me!

댓글을 달려면 로그인하십시오.

카테고리

Help CenterFile Exchange에서 Connectivity to TI mmWave Radar and DCA1000EVM to Capture Raw ADC Data에 대해 자세히 알아보기

제품


릴리스

R2024b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!