Synchronous generator not responding correctly to loss of load

조회 수: 8 (최근 30일)
Gordon Elgin
Gordon Elgin 2024년 11월 26일
이동: Sabin 2025년 2월 10일
I’m doing a simple analysis of a synchronous machine running as a generator supplying a couple of loads. When power generated is greater than power demand there should be a frequency rise at the generator via the swing equation. However, doing multiple prebuilt simulations and tripping off load instead of rising frequency it’s always drops. I’ve adjusted inertia, governor valve settings, damping settings, time delay setting of governor.
  댓글 수: 2
Raghava S N
Raghava S N 2024년 11월 26일
Could you share the Simulink model you are working with?
Gordon Elgin
Gordon Elgin 2024년 11월 26일
Here's the simulink model I was working with. All it is a diesel generator and then a couple of resistive loads.

댓글을 달려면 로그인하십시오.

답변 (1개)

Gordon Elgin
Gordon Elgin 2024년 11월 26일
이동: Sabin 2025년 2월 10일
Just an update on my question. The reasoning for the error was within the breaker. Actually a signal of 0 actives the breaker and a signal of 1 deactivates the breaker. I was actually removing load instead of adding it.
  댓글 수: 2
Shivam Gothi
Shivam Gothi 2024년 11월 26일
이동: Sabin 2025년 2월 10일
Is the error resolved ?
Gordon Elgin
Gordon Elgin 2024년 11월 26일
이동: Sabin 2025년 2월 10일
Yes