FMU issue while setting parameter

조회 수: 17 (최근 30일)
Saurabh Dhakate
Saurabh Dhakate 2024년 10월 28일 16:06
답변: Gayatri 2024년 10월 28일 16:11
We have an FMU that imports successfully into Simulink. However, I'm struggling to set parameters from the workspace. I've tried using various Simulink callbacks but it doesn't seem to affect the FMU's parameters. I want to set parameters once at the start of the simulation.

채택된 답변

Gayatri
Gayatri 2024년 10월 28일 16:11
Hi Saurabh,
You can modify the parameters using the following MATLAB commands:
blockPath = 'model_name/block_name';
blockHandle = getSimulinkBlockHandle(blockPath, true);
set_param(blockHandle, 'parameter_name', 'parameter_value');
Please refer the below documentations for 'set_param' and 'getSimulinkBlockHandle' functions:
I hope it helps!

추가 답변 (0개)