How to change all the block and signal names in Simulink to lower case in one instant?

조회 수: 30 (최근 30일)
I want to change all the signal names and block names in the Simulink model to lower case in one instant. How to achieve this?

채택된 답변

MathWorks Support Team
MathWorks Support Team 2024년 10월 8일 0:00
편집: MathWorks Support Team 2024년 10월 8일 15:20
As of MATLAB R2024a, you will need to manually change all the names to lowercase or write a custom script to achieve this. To convert all block names in your Simulink model to lowercase, you can follow these steps to create a custom script:
  1. Obtain the names of all the blocks in your Simulink model using the "get_param" method.
  2. Convert these names to lowercase using the "lower(str)" function.
  3. Update the block names by applying the "set_param" method.
    Below is an example script to convert all block names to lowercase:
    % Open your Simulink model modelName = 'your_model_name'; % Replace with your model name open_system(modelName); % Get all block handles in the model blocks = find_system(modelName, 'Type', 'Block'); % Loop through each block to process names for i = 1:length(blocks) % Get the current block's name currentBlock = blocks{i}; blockName = get_param(currentBlock, 'Name'); % Convert the block name to lower case newBlockName = lower(blockName); % Change the block name using set_param if the name has changed if ~strcmp(blockName, newBlockName) set_param(currentBlock, 'Name', newBlockName); end end % Save and close the model save_system(modelName); close_system(modelName);

    추가 답변 (0개)