switching of svpwm is not working . it is not showing staircase mode in scope

조회 수: 3 (최근 30일)

채택된 답변

Fangjun Jiang
Fangjun Jiang 2024년 8월 13일
편집: Fangjun Jiang 2024년 8월 14일
To convert radians to degree, the Gain should be 180/pi. You had it as pi/180. That seems to be the cause.
The logic seems correct, although a single Lookup Table block can replace all those blocks, mapping 0~60 to 1, 60~120 to 2, etc.
  댓글 수: 1
PARADESI
PARADESI 2024년 8월 16일
thank you
i have the stair case for the svpwm.
for the three phase grid connected system should i have used the angle from pll and i'm experiencing exponentially increasing waveform. what should i do to settle it down