e-NTU generic table dimensions discrepancy

조회 수: 6 (최근 30일)
Georgiy Tanasov
Georgiy Tanasov 2023년 8월 16일
답변: Muskan 2023년 9월 4일
Why by default in the e-NTU heat transfer block both NTU and Cr vectors are 5 dimensional but resulting effectiveness table is 5x6? Where is the last dimension coming from?
  댓글 수: 1
Yifeng Tang
Yifeng Tang 2023년 8월 18일
The default vector of NTU, on my end, is [.5, 1, 2, 3, 4, 5], a 1x6 vector. The default of CR is [0, .25, .5, .75, 1], 1x5 vector. The effectiveness table is 6x5.
Is that not what you have as default?

댓글을 달려면 로그인하십시오.

답변 (1개)

Muskan
Muskan 2023년 9월 4일
Hi Georgiy,
As per my understanding, the additional dimension in the effectiveness table comes from the inclusion of a "0" value in the Cr vector. The Cr vector represents the capacity ratio, which is the ratio of heat capacities between the hot and cold fluid streams. The "0" value in the Cr vector corresponds to the case when the heat capacity of the hot fluid stream is negligible compared to the cold fluid stream.
You can refer to the following documentation for a better understanding of the question:
https://in.mathworks.com/help/hydro/ref/entuheattransfer.html
I hope the above information helps resolve your query.
Thanks