Why I can not to connect Switch with PV panel directly ?

조회 수: 1 (최근 30일)
Koran Namuq
Koran Namuq 2022년 10월 9일
편집: Walter Roberson 2022년 10월 9일
Kindly Anyone can help
I would like to connect two relay(Switch ) with two panels to change type of connection from parallel to series or from series to parallel depending on output voltage
so I cant connect pv panel with switch why ?
any one have Idia please

채택된 답변

Walter Roberson
Walter Roberson 2022년 10월 9일
편집: Walter Roberson 2022년 10월 9일
you are using https://www.mathworks.com/help/simulink/slref/switch.html which is a switch for Simulink signals. However your inputs are electrical voltages not numeric signals.
You need a switch from the electrical library, https://www.mathworks.com/help/sps/powersys/ref/idealswitch.html
Simulink supports several different "domains" that can only be connected through convertor blocks. Pure signals, electrical signals, fluids: Simulink makes sure that you keep them separate.
  댓글 수: 2
Walter Roberson
Walter Roberson 2022년 10월 9일
Remember though that an ideal electric switch does not correspond to reality. In reality you have to be concerned with overshoot and transients. If you were doing high frequency work those can become substantial problems.
Koran Namuq
Koran Namuq 2022년 10월 9일
thanl you very much your notification was very useful