Battery SOC is showing 0 reading in scope while discharging

조회 수: 1 (최근 30일)
Armaghan Arshad
Armaghan Arshad 2022년 7월 15일
답변: Xiangchun 2023년 10월 20일
i am trying the given model but i am not getting proper SoC graph its showing 0 throughout the execution the model, graph and setting of battery are given below kindly give feedback what actually wrong with the settings thanks

답변 (1개)

Xiangchun
Xiangchun 2023년 10월 20일
Hi Armaghan,
The SOC physical signal from the Battery (Table-Based) block goes through PS-Simulink Converter before it becomes a Simulink signal that is suitable for display on the Scope. From the screenshot, it appears that there are two PS-Simulink Converters for the SOC signal converstion. Only one is needed. Please double check the model and connections to verify if that is indeed the case.
Best wishes,
Xiangchun