How can i fix this error in the Impulse Response Measurer?

조회 수: 3 (최근 30일)
Mehmet Cibir
Mehmet Cibir 2022년 1월 18일
댓글: Jimmy Lapierre 2022년 1월 21일
Hi,
since today i have the problem that i get the following error message in the "impulse response measurer" (see picture) and actually no data is recorded.
I haven't found a workaround for this yet. Has something similar already happened to someone ?
Thanks in advance!

채택된 답변

Jimmy Lapierre
Jimmy Lapierre 2022년 1월 19일
Hi Mehmet, could you try increasing the “Duration per run” relative to the “sweep duration”. The sweep methods requires this period of silence after the sweep to record the response.
It appears you found a case where the error message is of no help, we will fix that.
  댓글 수: 2
Mehmet Cibir
Mehmet Cibir 2022년 1월 21일
Hi Jimmy,
thank you for your response!
It seems that increasing the "Duration per run" relativ to the "sweep duration" solves the issue.
I have tried it with different settings and have so far got no new error message.
Jimmy Lapierre
Jimmy Lapierre 2022년 1월 21일
Great to hear! We'll improve that error message nevertheless.

댓글을 달려면 로그인하십시오.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Audio and Video Data에 대해 자세히 알아보기

제품


릴리스

R2021b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by