How to acquire and generate data using NI DAQ simultaneously on a continuous basis

조회 수: 5 (최근 30일)
I have an NI input (9205) and NI output (9263) modules. I am trying to acquire and generate data in the same session but on a continuous basis. In this regard I referred to the tutorial provided for simultaneous acquisition and generation.
However when I try to do this on a continuous basis that is for an infinite amount of time I get the error : The data argument must contain one column for each output channel in the session.
I have pasted the code below.
function acquire_generate
clc;
global indata;
global outdata;
s3= daq.createSession('ni');
ch1= addAnalogInputChannel(s3,'cDAQ1Mod2','ai19','Voltage');
addAnalogOutputChannel(s3,'cDAQ1Mod7','ao0','Voltage');
ch1.InputType= 'SingleEnded';
s3.IsContinuous= true;
lh= s3.addlistener('DataAvailable',@plotData);% to plot acquire data in real time
s3.NotifyWhenDataAvailableExceeds=1000;
outdata= indata/2;
queueOutputData(s3,outdata);
lh1=s3.addlistener('DataRequired',@queueMoreData); % adding a listener to queue output data continuously
s3.startBackground();
while s3.IsRunning % to prevent Timeout
pause(0.5);
end
close(gcf);
figure(1);
plot(indata);
figure(2);
plot(outdata);
end
function plotData(src,event)
persistent localData;
global indata;
if(isempty(localData))
localData=[];
disp('acquiring starting');
end
plot(event.TimeStamps,event.Data);
localData= [localData;event.Data];
indata= localData;
if(max(event.Data)<5);
disp('Stopping acquire')
src.stop()
plot(event.TimeStamps,event.Data);
end
end
function queueMoreData(src,event)
global outdata;
queueOutputData(s3,outdata);
end
I am unable to figure out what I am doing wrong. Comments and insights will be appreciated. Thank you.
Regards,
Sri

채택된 답변

Michael
Michael 2014년 10월 17일
편집: Michael 2014년 10월 17일
I was having a different problem where I couldn't acquire for more than a few seconds.
for your problem, Srikrishnan, I'd start with the change below
ch(1) = addAnalogInputChannel(s3,'cDAQ1Mod2','ai19','Voltage');
ch(2) = addAnalogOutputChannel(s3,'cDAQ1Mod7','ao0','Voltage');
I was able to find that on Acquire Data and Generate Signals Simultaneously they say "When the session contains output channels, duration and number of scans become read-only properties of the session. The number of scans in a session is determined by the amount of data queued, and the duration is determined by s.ScansQueued/s.Rate.
Playing around with s.NotifyWhenDataAvailableExceeds fixed my problem.

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Data Acquisition Toolbox Supported Hardware에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by