Slow simulation with noisy output
조회 수: 1 (최근 30일)
이전 댓글 표시
Hi,
i have this issue with slow simulation time for a stable first order tranfers function.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/145268/image.png)
I've tested it with and without the Dead zone and I get the same results. The Scope1 show a intense oscillation of the output.
Thanks
Alexandre
댓글 수: 1
Aniruddha Katre
2014년 9월 3일
This behavior stems from the fact that the time-step taken by the solver is so large that it fails to capture the dynamics of the system, which has a bandwidth of 200000 rad/s.
Consistent with the Nyquist sampling theorem, if you run the simulation using a fixed-step solver with step size of around 1/400000, then you will not observe this kind of oscillation.