Why the volumic flow rate sensor (motion air) is registering a negative value?

조회 수: 7 (최근 30일)
Karl Schaan
Karl Schaan 2021년 9월 3일
답변: Yifeng Tang 2022년 7월 29일
Hello,
I'm trying to modeling a Environmental Control System (ECS), where a DC Motor drive a Turbine (HVAC library). To do so I am using a 2-Port Constant Volume Chamber (MA). However, the Volumic Flow Rate Sensor (MA) is registering a negative value. The Pressure is 1.103 atm and the Temparture is 20 °C in the moist air network.
Is there a better way to model an ECS with the available Simscape resources? I have also tried to use the Rotational Mechanical Converter (MA) but it's the same problem.
I have attached the model.
Thanks in advance for any help.
Cheers,
Karl

답변 (1개)

Yifeng Tang
Yifeng Tang 2022년 7월 29일
As @VBBV mentioned in the comment, switching the A/B port is likely the solution.
Is this turbine block the same one as in theAircraft Environment Control System demo? If so, the flow is expect to flow into the A port when the R port has a positive rotation. I'm a bit confused by the A port of the turbine connected to "Out air" though. When air flows into the A port of the turbine, it's flow from the B port of the flow sensor to the A port. By the definition of the sign in this sensor, it's negative flow. In the documentation, it states: The relative orientation of ports A and B establishes the measurement sign. The sign is positive if flow occurs from port A to port B. Switching port connections reverses the measurement sign.

카테고리

Help CenterFile Exchange에서 Foundation and Custom Domains에 대해 자세히 알아보기

제품


릴리스

R2018b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by