problem in simulink connections..??

조회 수: 6 (최근 30일)
prasha
prasha 2014년 1월 13일
답변: Kaustubha Govind 2014년 3월 20일
hi... i am trying to connect the op-amp with the analoge filter but it shows the red line(not connected)so how can i get the connections..please help me..i need to make the circuit nd b'coz of not getting connections i am not able to move futher...:(

채택된 답변

Mischa Kim
Mischa Kim 2014년 1월 13일
편집: Mischa Kim 2014년 1월 13일
Make sure to drag the signal line all the way from the output of one block to the input of the other.
For connecting Simulink to PhysMod (SimRF, etc.) blocks see the documentation (assuming you are talking about SimRF components in this case).
  댓글 수: 1
prasha
prasha 2014년 1월 13일
this is not the problem..Mischa Kim....actually i am trying to connect the design of charge amplifier output to the high pass filter in simulink(analoge fillter design)but the connection shows the red dot...

댓글을 달려면 로그인하십시오.

추가 답변 (1개)

Kaustubha Govind
Kaustubha Govind 2014년 3월 20일
It looks like one of your blocks works with physical signals, but the other using regular Simulink signals. You will need to use the S->PS or PS->S blocks to connect them. Please see this previously answered question for more information.

카테고리

Help CenterFile Exchange에서 RF Blockset Models for Transceivers에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by