Hanning window pole zero

조회 수: 8 (최근 30일)
romi
romi 2013년 12월 27일
답변: Honglei Chen 2013년 12월 27일
i want design FIR filter digital method with Hanning window but i've a trouble. In part of filter specify order, i want 20 order's but in part of current Filter Information looks "Order : 19". why this happening? thanks

답변 (1개)

Honglei Chen
Honglei Chen 2013년 12월 27일
Hi Romi,
It seems to be a bug in FDATool. The display panel is giving out the wrong answer. The designed filter is indeed a filter of order 20. If you look at the coefficients or the impulse response, there are indeed 21 coefficients. Thanks for reporting the issue.

카테고리

Help CenterFile Exchange에서 Digital Filter Analysis에 대해 자세히 알아보기