Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
댓글 수: 1
Kaustubha Govind
2011년 6월 27일
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
채택된 답변
Nuno
2011년 6월 29일
댓글 수: 4
Arnaud Miege
2011년 6월 30일
OK, try putting a resistor in parallel with the Controlled Current Source and see if that fixes it.
추가 답변 (3개)
Arnaud Miege
2011년 6월 28일
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud