Main Content

getZOdd

Calculate odd mode impedance of differential PCB transmission line

Since R2022b

Description

example

zodd = getZOdd(txline,frequency) calculates the odd mode impedance of the transmission lines in Transmission Lines at the specified frequency.

Examples

collapse all

Create a coupled microstrip line with copper traces.

txline = coupledMicrostripLine;
txline.Conductor.Name = "Copper";
txline.Conductor.Conductivity = 5.8e7;
txline.Conductor.Thickness = 0.001;

Calculate the odd mode impedance of coupled microstrip line at 1 GHz.

freq = 1e9;
oddImp = getZOdd(txline,freq)
oddImp = 42.5414

Input Arguments

collapse all

Transmission line, specified as a coupledMicrostripLine, microstripLine, or microstripLineCustom object.

Example: txline = microstripLine;getZOdd(txline). Calculates the odd mode impedance of the microstrip transmission line object with handle txline.

Data Types: char | string

Frequency to calculate the odd mode impedance, specified as a positive scalar in hertz.

Output Arguments

collapse all

Odd mode impedance of the transmission line, returned as a complex scalar.

Data Types: double

Version History