Loss Calculation in a 3-Phase 3-Level Inverter Using SimPowerSystems and Simscape

버전 1.0.0.0 (1.2 MB) 작성자: Pierre Giroux
SimPowerSystems(SPS) and Simscape are used to calculate losses in a 3-phase, 3-level inverter.
다운로드 수: 4.9K
업데이트 날짜: 2012/4/12

라이선스 보기

From a +/- 1800 volts DC source, a 400-kW, 3-phase 3-level inverter delivers variable power to a
distribution power system. The inverter output is connected to the 25-kV, 40 MVA, 50-Hz system
through a 2200 V / 25 kV transformer.

Each 3-level leg of the 3-phase 400-kW inverter comprises three commercial half-bridge IGBT modules. Phase-A leg is implemented using the “Half-bridge IGBT with Loss Calculation” block provided in a SPS local library. Based on the thermal characteristics of the selected IGBT module, both switching and conduction losses are calculated. Thermal blocks of the Simscape foundation library are used to model the heat dissipation provided by the heat sink. The simulation illustrates the achievable output power versus switching frequency for the 3-phase, 3-level inverter and compares results with the manufacturer’s reference document.

A Help file containing useful information on the model is also included.

Authors: Pierre Giroux, Gilbert Sybille, Olivier Tremblay
Hydro-Quebec Research Institute (IREQ)

인용 양식

Pierre Giroux (2024). Loss Calculation in a 3-Phase 3-Level Inverter Using SimPowerSystems and Simscape (https://www.mathworks.com/matlabcentral/fileexchange/36158-loss-calculation-in-a-3-phase-3-level-inverter-using-simpowersystems-and-simscape), MATLAB Central File Exchange. 검색됨 .

MATLAB 릴리스 호환 정보
개발 환경: R2012a
모든 릴리스와 호환
플랫폼 호환성
Windows macOS Linux
커뮤니티
 Power Electronics Control 커뮤니티에 더 많은 파일이 있습니다

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

LossCalculation_3Phase3LevelInverter/

버전 게시됨 릴리스 정보
1.0.0.0