I can not use functions for NI device
이전 댓글 표시
I found I can not use some functions when I tried to acquire data with ni product usb-6008.
for example,
s = daq.createSession('ni'),daq.getDevices,addAnalogInputChannel.
I can not use them, the error is: Undefined variable "daq" or class "daq.createSession". Undefined function or variable 'daq'.and so on. what's the matter?
답변 (3개)
Walter Roberson
2013년 7월 31일
You do not have the DAT installed, or not licensed, or you are using a version of MATLAB that does not support session based acquisition.
Which MATLAB release are you using?
Does
which -all daq
show any result?
댓글 수: 2
Walter Roberson
2013년 7월 31일
The first support for session-based interfaces was R2010b, the release after the one you had. With your software you will need to use the legacy interface.
Note: not all NI devices were supported in R2010b; more devices were added with each release from R2010b.
댓글 수: 2
mado
2013년 8월 1일
Walter Roberson
2013년 8월 1일
I already responded above. Your version does not support session-based interface at all.
Eric Keller
2013년 8월 1일
0 개 추천
if you have a 32 bit system and can't upgrade matlab, use the legacy interface.
카테고리
도움말 센터 및 File Exchange에서 Real-Time Deployment and Code Generation에 대해 자세히 알아보기
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!