필터 지우기
필터 지우기

System Identification Toolbox not importing data properly

조회 수: 3 (최근 30일)
fmo2641
fmo2641 2020년 12월 11일
댓글: fmo2641 2021년 1월 29일
I am using the system identification toolbox to identify a transfer function using a bode plot. I have used it in the past without much errors
I'm currenlty using: import data --> frequency domain data --> frequency function (Amp/Phase)
The the amplitude that is imported seems to be backwards and scaled and the phase just seems to be scaled. I am not sure what is wrong, I have closed System Identification toolbox, restarted matlab, with no success
Update: The toolbox seems to take the absolute value of my amplitude plot and shift my phase to positive.
The following is the original data
The following is the imported data, it ooks very distorted and is clearly not what is in the original data.
Here are the settings I am using:

채택된 답변

Mathieu NOE
Mathieu NOE 2020년 12월 13일
hello
seems you are giving the amplitude in dB whereas the ID toolbox parameters is waiting for a linear scale amplitude
so you have to do first a dB to linear amplitude conversion
a_lin = 10.^(a_dB/20)

추가 답변 (0개)

카테고리

Help CenterFile Exchange에서 Linear Model Identification에 대해 자세히 알아보기

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by