i have emotiv epoch for EEG signal acquisition. If band width of Emotiv is 2-43 Hz and sampling frequency is 128 Hz then upto which i should apply DWT, On 2-43 Hz or On 128 Hz?????

채택된 답변

Wayne King
Wayne King 2013년 3월 3일
If your sampling frequency is 128 Hz, then the approximate frequency bands in the DWT are already determined by the sampling frequency.
They are: (Scaling filter band on left, wavelet filter band on right)
[0 32] [32 64] Hz
[0 16] [16 32] Hz
[0 8] [8 16] Hz
[0 4] [4 8] Hz
and so on.
You notice that the band 2-43 Hz is best localized (but certainly not perfectly) in the 1st level approximation coefficients.
What not just use a good filter if you are just using the DWT to perform a frequency-filtering of your signal?