필터 지우기
필터 지우기

Simulink Fuel Cell Stack - Hydrogen & Oxygen Utilization

조회 수: 6 (최근 30일)
Matthew Holt
Matthew Holt 2020년 2월 26일
답변: Joel Van Sickel 2021년 8월 17일
Within the Simscape Fuel Cell Stack Block, in the subsystem Uf calculator, 2 functions are used are labeled H2 Utilization Fuel Flowrate and O2 Utilization Air Flowrate.
These then connect to switches to determine whether to use the nominal utilization value for H2 and O2 respectively. However the output value of these functions is not a utilization value ie) % or decimal, but seem to be more inline with flowrate values.
Why is it that a switch is then used to determin if the nominal utilization value is used over the function output?

답변 (1개)

Joel Van Sickel
Joel Van Sickel 2021년 8월 17일
Hello Matthew,
this is a case where the model behaves differently depending on certain choices made in the mask of the component, so you are essentially looking at multiple versions of a model, as in once place. This can make it a bit more confusing to understand what the model is doing but makes the model more useful for different parameterizations and use cases. The values from these blocks are not utilization, but flow rates.
Regards,
Joel

카테고리

Help CenterFile Exchange에서 Simscape에 대해 자세히 알아보기

제품


릴리스

R2019b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by