Simulink 2019a To Workspace/Array gives a structure not an array

조회 수: 6 (최근 30일)
Charles B
Charles B 2019년 9월 23일
댓글: Ibrahim A. Shaaban 2021년 10월 8일
I created a simple model with a step source and a To Workspace sink. I changed the Save Format to Array and ran the model. The data in the workspace appears as a structure, not an array. Is this a bug? I don't recall it worked this way in 2018b. How can I change the settings so the data is saved as an Array?Capture.PNG

답변 (1개)

Urmila Rajpurohith
Urmila Rajpurohith 2020년 4월 9일
Data in workspace appears as structure because single simulation ouput option is checked which return all simulation outputs as a single Simulink.SimulationOutput object
unchecking this option will give you the data in array format
To uncheck this option go to:
Modelconfiguration parameters -->Data import/export and uncheck single simulation ouput