I am getting the following error
'MyTopLevelModel/SubsystemA/Model' has multiple sample times. Only constant (inf) or inherited (-1) sample times are allowed in function call subsystem 'MyTopLevelModel/SubsystemA'.
More info of my setup
SubsystemA has a function call which has a trigger port connected to a port set as "output function call with sample time of 0.001. All my other blocks have sample time -1 (inheritet).
If I go to the model explorer the compiled sample time are not [-1 0] some of the have set the [0.001 0]
Any idea what could be causing this error ?
  댓글 수: 3
ricard molins
ricard molins 2019년 2월 20일
Can't share the model. Thats the reason I am asking for guidance of where could the potential error be and not a specific solution to my issue.
Arvind Sathyanarayanan
Arvind Sathyanarayanan 2019년 2월 20일
To identify which block(s) have a different sample time goto Display ->Sample TImes -> Colors.

댓글을 달려면 로그인하십시오.

채택된 답변

ricard molins
ricard molins 2019년 2월 22일
The problem was that a configuration reference had a time step set to 0.01. This time step was transformed into a CompiledTimeStep and therefore it set a CompiledTimeStep different to -1 or inf. Setting the time step to auto solved the issue.

추가 답변 (1개)

dc
dc 2023년 4월 23일
it is very puzzle;you need configure the function call ‘s sample time in the runnable/system;i mean the display of f() . do not configure reference

카테고리

Help CenterFile Exchange에서 Simulink에 대해 자세히 알아보기

태그

제품


릴리스

R2016a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by