Why Steady-state Pressure drop across a simple pipe in Simscape not in line with the manual calculation?

조회 수: 4 (최근 30일)
I have a constant gas flow source connected with a pipe model. The mass flow is 2 kg/s. The pipe is with diameter 160mm, length 100m. I have attached the simulink model.
According to help page, I calculated the pressure drop as 128 * mu_I * m_dot * Length / (rho_I * pi * D^4) ~= 180 Pa if mu_I = 18 * 10 ^(-6) and rho_I is 1.2 kg/m^3 for air at 20 degree.
The simscape simulation shows the pressure drop is 9000 Pa (see figure below), which is way off than the calcuated value. I know the density is underestimated as the steady-state pressure is 3.5 bar instead of 1 ATM. If taking that into account, the calculated value is even smaller.
Since 3.5 bar is not a very high pressure, I pressume the dynamic viscosity is not too much affected by the pressure. mu_I = 18 * 10 ^(-6) is perhaps acceptable in the calculation? Could anyone help to explain where the calculation went wrong or why this discrepancy happens? THANKS.

답변 (0개)