Sample time setting for high frequency systems
조회 수: 2 (최근 30일)
이전 댓글 표시
What sample time should I use when simulating a system operating at 100 kHz?
It seems to me that the typical 0.2 seconds would be to small.
Are there quidelines for determining the appropriate sample time?
댓글 수: 0
답변 (2개)
Fangjun Jiang
2011년 8월 15일
A 100kHz signal means its period is 10us. If the signal is a sine wave, you would need about 20 data points to represent a complete cycle of a sine wave with good quality. That means 0.5us is your maximum step size or sample time. 0.2 seconds is way bigger.
댓글 수: 0
Stephen
2011년 8월 15일
댓글 수: 1
Fangjun Jiang
2011년 8월 15일
Sure. The proper sample time should be determined by the need of the application. To measure the noise level and temperature of a living room, for example, could have quite different sample time.
참고 항목
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!