Model Representation for Analysis
When you analyze a model for the first time, Simulink® Design Verifier™ performs a compatibility check and creates a model representation. The model representation contains information about model behavior to use for analysis. By default, the software saves the model representation at the Simulation cache folder location.
If you modify a model and rerun the analysis, Simulink
Design Verifier determines whether to rebuild the model representation or to use the
existing Simulink cache depending on the Rebuild model representation parameter. A rebuild
of the model representation is triggered, when the Rebuild model
representation option is set to If change is
detected
and the software detects any changes in the model.
Reuse Model Representation for Analysis
The Rebuild model representation option is set to
If change is detected
by default and the software
validates the model representation against any model changes and Simulink
Design Verifier analysis options. The software then determines whether to reuse or to
rebuild the model representation for analysis. When you set the option to
Always
, the model representation is rebuilt during
every model analysis.
When the Rebuild model representation option is set to
If change is detected
, Simulink
Design Verifier checks for these changes in a model:
Simulink Design Verifier Options
The software validates the model representation against any changes in the Simulink Design Verifier options. This table lists the options that do not affect the model representation, and if you change any of these options the software reuses the model representation.
Design Verifier Options | |
Test Generation options | |
Property Proving options | |
Results generation options | |
Report generation options |
Structural Checksum of a Model
The Simulink Design Verifier uses both structural checksum and code checksum. A structural checksum is a computation that detects changes in the model that can affect simulation results. For more information about the kinds of changes that affect the model, see Rebuild.
Note
When you Generate Test Cases for Embedded Coder Generated Code, Simulink Design Verifier also considers checksum of the generated code.
Additional Dependencies
In addition to structural checksum, Simulink Design Verifier checks for changes in model dependencies that can impact the analysis results, such as:
Simulation run-time parameters that are defined in the data dictionary or the MATLAB® base, mask, or model workspaces
External C or C++ source code files that the model uses during simulation
Minimum and maximum constraints that are specified for block parameters
Block parameters that are specified for blocks in the Simulink Design Verifier Block Library, such as Values
Limitations
The model representation is always rebuilt:
When Simulink Design Verifier analysis is started from other products such as Simulink Test™, Simulink Coverage™, Simulink Check™, and Requirements Toolbox™.
When the model contains MATLAB System blocks.
Simulink Design Verifier does not detect changes in the custom block replacement rules that you apply, even if the Rebuild model representation option is set to
If change is detected
. In such cases, the Simulink cache is reused for analysis and a warning message is displayed in the Diagnostic Viewer that suggests you to set the Rebuild model representation option toAlways
, if you want to rebuild the model representation.
See Also