주요 콘텐츠

Modbus

Communicate with Raspberry Pi® hardware using Modbus® protocol

Use the Modbus request-response protocol to implement a client-server architectural system that facilitates communication between Raspberry Pi hardware and peripheral devices.

Blocks

Modbus TCP/IP Client ReadClient device reads data from server device register(s) over TCP/IP network
Modbus TCP/IP Client WriteClient device writes data to server device register(s) over TCP/IP network
Modbus TCP/IP Server ReadServer device reads data from server device register over TCP/IP network
Modbus TCP/IP Server WriteServer device writes data to server device register over TCP/IP network

Model Settings

expand all

Communication interfaceExchange data between host computer and target hardware
ModeModbus mode of operation for Simulink model
Remote Server IP port numberIP port number of client device
Local IP port numberIP port number of server device(s) connected on TCP/IP network
Configure CoilsConfigure the starting address and number of coil registers
Start addressStarting address of the coil register
QuantityNumber of coil registers
Configure Discrete InputsConfigure the starting address and number of discrete input registers
Start AddressStarting address of the discrete input register
QuantityNumber of discrete input registers
Configure Holding registersConfigure starting address and number of holding registers
Start addressStarting address of the holding register
QuantityNumber of holding registers
Configure Input registersConfigure starting address and number of input registers
Start addressStarting address of the input register
QuantityNumber of input registers
Received timeout (ms)Maximum time in milliseconds that block should wait for response

Topics