Check safety-related solver settings for simulation time
Check ID:
mathworks.hism.hisl_0040
Check solver settings in the model configuration that apply to simulation time and might impact safety.
Description
This check verifies that the model solver configuration parameters pertaining to simulation time are set optimally for generating code for a safety-related application.
Available with Simulink® Check™.
Results and Recommended Actions
Condition | Recommended Action |
---|---|
The solver setting to specify the start time for the simulation
or generated code is set to a value other than
| In the Configuration Parameters dialog box, set Start time or set the parameter
|
The solver setting to specify the stop time for the simulation
or generated code is set to a negative value or a positive value
greater than the value of Application lifespan (days). By default, Application lifespan (days) is | In the Configuration Parameters dialog box, set Stop time or set the parameter
|
Action Results
Clicking Modify Settings configures model diagnostic settings that apply to solvers and that can impact safety.
Capabilities and Limitations
Does not run on library models.
Does not allow exclusions of blocks or charts.
Analyzes content in masked subsystems.