Series R
Model series resistor
Libraries:
RF Blockset /
Equivalent Baseband /
Series /
Shunt RLC
Description
The Series R block models the series resistor described in the block dialog box, in terms of its frequency-dependent S-parameters.
The series R object is a two-port network, as shown in the following circuit diagram.
![]()
Parameters
Main
Resistance value, specified as a scalar.
Visualization
Frequency data source, specified as
User-specified.
Frequency data range, specified as a vector in hertz.
Reference impedance, specified as a nonnegative scalar in ohms.
Type of data plot to visualize using the given data, specified as one of the following:
X-Y plane— Generate a Cartesian plot of the data versus frequency. To create linear, semilog, or log-log plots, set the Y-axis scale and X-axis scale accordingly.Composite data— Plot the composite data. For more information, see Create Plots Using Equivalent Baseband Library Blocks.Polar plane— Generate a polar plot of the data. The block plots only the range of data corresponding to the specified frequencies.Z smith chart,Y smith chart, andZY smith chart— Generate a Smith® chart. The block plots only the range of data corresponding to the specified frequencies.
Type of parameters to plot based on the Plot type you set, specified as one of the following.
| Plot type | Y parameter1 |
|---|---|
X-Y plane | S11, S12, S21, S22, GroupDelay, OIP3, NF, NFactor, and NTemp. |
Composite data | No Y parameter1 to set. |
Polar plane | S11, S12, S21, and S22 |
Z Smith chart | S11 and S22. |
Y Smith chart | S11 and S22. |
ZY smith chart | S11 and S22. |
Type of parameters to plot based on the Plot type you set, specified as one of the following.
| Plot type | Y parameter2 |
|---|---|
X-Y plane | S11, S12, S21, S22, GroupDelay, OIP3, NF, NFactor, and NTemp. |
Composite data | No Y parameter2 to set. |
Polar plane | S11, S12, S21, and S22 |
Z Smith chart | S11 and S22. |
Y Smith chart | S11 and S22. |
ZY smith chart | S11 and S22. |
Plot format, specified as one of the following.
| Y parameter1 | Y format1 |
|---|---|
S11, S12, S21, and S22. | Magnitude (decibels), Magnitude (linear), Angle(degrees), Angle(radians), Real, and Imaginary. |
GroupDelay | ns, us, ms, s, and ps. |
OIP3 | dB, dBm, W, and mW. |
NF | Magnitude (decibels) |
NFactor | None |
NTemp | Kelvin |
Dependencies
To enable Y format1, set Plot type to X-Y plane.
Plot format, specified as one of the following.
| Y parameter2 | Y format2 |
|---|---|
S11, S12, S21, and S22. | Magnitude (decibels), Magnitude (linear), Angle(degrees), Angle(radians), Real, and Imaginary. |
GroupDelay | ns, us, ms, s, and ps. |
OIP3 | dB, dBm, W, and mW. |
NF | Magnitude (decibels) |
NFactor | None |
NTemp | Kelvin |
Dependencies
To enable Y format2, set Plot type to X-Y plane.
Frequency plot, specified as Freq.
Frequency plot format, specified as one of the following.
Auto | Hz | kHz | MHz |
GHz | THz |
Y-axis scale, specified as Linear or Log.
Dependencies
To enable this parameter, set Plot type to X-Y
plane.
X-axis scale, specified as Linear or Log.
Dependencies
To enable this parameter, set Plot type to X-Y
plane.
Plot the specified data using the plot button.
Version History
Introduced before R2006a
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
웹사이트 선택
번역된 콘텐츠를 보고 지역별 이벤트와 혜택을 살펴보려면 웹사이트를 선택하십시오. 현재 계신 지역에 따라 다음 웹사이트를 권장합니다:
또한 다음 목록에서 웹사이트를 선택하실 수도 있습니다.
사이트 성능 최적화 방법
최고의 사이트 성능을 위해 중국 사이트(중국어 또는 영어)를 선택하십시오. 현재 계신 지역에서는 다른 국가의 MathWorks 사이트 방문이 최적화되지 않았습니다.
미주
- América Latina (Español)
- Canada (English)
- United States (English)
유럽
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)