Simscape HDL Workflow Advisor Tips and Guidelines

By using the Simscape HDL Workflow Advisor, you can generate an HDL implementation model. You can generate HDL code for the implementation model and deploy the generated code onto FPGA platforms. To open the Advisor, run the sschdladvisor function. For example:

openExample('plantdeployment/OpenTheSimscapeHDLWorkflowAdvisorExample','supportingFile','sschdlexBoostConverterExample')
sschdladvisor('sschdlexBoostConverterExample')

The Simscape HDL Workflow Advisor contains various tasks that convert your Simscape™ model to the HDL implementation model. When running various tasks in the Simscape HDL Workflow Advisor, you can follow certain tips and guidelines. You see these tips in the UI window of a particular task. For example, in the task that discretizes the equations to state-space parameters, the UI has a tip that suggests how to change the sample time. This section contains more information about each tip in the Simscape HDL Workflow Advisor UI.

Estimating Resource Consumption Using Algebraic and Differential Variables

After you run the Check model compatibility task, the task reports the number of differential and algebraic variables for each Simscape network present in the model. For example, this figure illustrates that there are two differential and two algebraic variables in the boost converter example model sschdlexBoostConverterExample.

openExample('plantdeployment/OpenTheSimscapeHDLWorkflowAdvisorExample','supportingFile','sschdlexBoostConverterExample')
sschdladvisor('sschdlexBoostConverterExample')

Run the workflow to the Check model compatibility task.

By viewing the number of algebraic and differential variables, you can determine how the design consumes resources on the FPGA device. If Nd is the number of differential variables and Na is the number of algebraic variables, the resource usage on the target hardware varies according to the relation Nd*(Nd+Na). Differential variables consume a quadratic amount of multiplier resources on the target FPGA device. Algebraic variables consume a linear amount of multiplier resources. You can use this information to determine how many multiplier resources your Simscape design consumes on the FPGA device and whether your design is ready for conversion to state-space representation.

Setting Simulation Stop Time for Extract Discrete Equations

Change Simulation Stop Time

When you run the Extract discrete equations task, the Simscape HDL Workflow Advisor reports the simulation stop time. The simulation stop time corresponds to the amount of time that the Advisor takes to run simulation on your Simscape model. The stop time must not be significantly large such that the Advisor takes a long time to run this task. Use a stop time that is sufficient to reach the required number of modes for your model. To change the stop time, navigate to the Simscape model, and then specify the Stop Time.

Simulation Stop Time and Number of Modes

In the Extract discrete equations task, when you extract the differential algebraic equations, the Simscape HDL Workflow Advisor simulates the model to cover the nonlinear range of Simscape blocks. This task can take a long time depending on the number of switching elements in the Simscape model.

For a switched linear model, each switching element in the design has two modes. A switched linear model with n switching elements has 2^n possible modes. For Simscape models with large number of switching elements, the number of modes can become significantly large. For example, the Vienna rectifier has 21 switching elements, which translates to 2^21 possible modes. The Simscape HDL Workflow Advisor can take a long time to simulate such a large model and cover such a large number of modes. In addition, the HDL implementation model that you generate for such a design can consume a large amount of resources or may not even fit on the target FPGA device.

In most cases, while simulating the model, the Advisor does not have to reach the entire 2^n modes. For example, consider this bridge rectifier model. To open this model, enter:

openExample('plantdeployment/BridgeRectifierModelExample','supportingFile','sschdlexBridgeRectifierExample')

Inside the Simscape_system Subsystem, you see the four diodes arranged in a bridge configuration.

As each diode has two states, the Simscape design can have 2^4 = 16 possible states. In contrast, the bridge rectifier has only three modes. The modes are:

  • Diodes D1 and D2 are ON, D3 and D4 are OFF

  • Diodes D1 and D2 are OFF, D3 and D4 are ON

  • Diodes D1, D2, D3, and D4 are OFF

This example shows that, based on the Simscape algorithm and the input to the design, you can set the simulation stop time to a minimum value that covers the number of modes to be reached.

Changing Sample Time for Extract Discrete Equations

Change Sample Time

When you run the Extract discrete equations task, the Simscape HDL Workflow Advisor reports the discrete sample time. The discrete sample time corresponds to the sample time that the Advisor uses to discretize the differential algebraic equations to state-space parameters. To change the sample time, in your Simscape model, open the Block Parameters dialog box for the Solver Configuration block, and then specify the Sample time.

Sample Time and Discretizing Equations

In the Extract discrete equations task, the Simscape HDL Workflow Advisor discretizes the differential algebraic equations into state-space parameters. You extract the differential algebraic equations by simulating the Simscape model. The task obtains the sample time information from the sample time that you specify for the Solver Configuration (Simscape) block in your model. The Advisor then discretizes the equations to state-space parameters based on this sample time information.

Using Number of Solver Iterations

What is Number of Solver Iterations?

On the Solver Configuration block, you can specify a custom value for the number of solver iterations in Nonlinear iterations text box when you select the Use fixed-cost runtime consistency iterations check box. The number of solver iterations refer to the number of times the state-space model is executed per mode. The Simscape HDL Workflow Advisor generates the number of iterations that are required for executing the state-space model, automatically.

For each mode in the physical system, the switched linear workflow arrives at a state-space representation. The solver method is iterative and performs multiple computations to determine the correct mode for the next time step. After a certain number of iterations, the output value from the next time step becomes the same as the value from the previous time step. This consistency in the output value indicates the correct number of solver iterations.

By default, the Number of Solver iterations is 1 for linear models. For switched linear models, the Number of solver iterations depends on the number of mode iterations that Simscape uses during model simulation. This chosen value is optimal such that it causes the model to converge and avoids exceeding the threshold value for real-time deployment.

Using Fixed-Cost Runtime Consistency Iterations

On the Solver Configuration block, the Use fixed-cost runtime consistency iterations check box is cleared by default. If you select this check box, the Nonlinear iterations setting on the Solver Configuration block allows you to specify the Number of solver iterations.

To learn more about the Use fixed-cost runtime consistency iterations setting, see Solver Configuration (Simscape). See also Solvers for Real-Time Simulation (Simscape).

Change Number of Solver Iterations

By default, you can change the number of solver iterations on this task. Increasing the number of solver iterations improves the numerical accuracy of generated HDL implementation model. To achieve higher sampling frequencies, reduce the number of solver iterations. Choose a value for number of solver iterations that trades off numerical accuracy and sampling frequency.

On the Solver Configuration block, if you select the Use fixed-cost runtime consistency iterations check box then you can change the number of solver iterations in the Nonlinear iterations parameter text box. Then, rerun the Generate implementation model task.

Trading off Numerical Accuracy and Sampling Frequency

To verify whether the numeric results of the HDL implementation model matches the original Simscape model, select Generate validation logic for the implementation model. If the numeric results from the HDL implementation model do not match, you can increase the number of solver iterations. To learn more, see Increase Number of Solver Iterations.

Changing the number of solver iterations trades off numerical accuracy for sampling frequency. Increasing the number of solver iterations increases the sample time of the HDL implementation model which can reduce the sampling frequency. See Reducing Number of Solver Iterations.

Data Type Precision and Numerical Accuracy

Use the Data type precision setting to specify whether you want the algorithm inside the HDL Subsystem in the generated implementation model to use single or double floating-point data type, or fixed-point data type when performing the matrix computations.

Data type precisionDescription
DoubleUsing double floating-point data type precision increases the numerical accuracy of the generated model and the maximum achievable target frequency. However, the area consumption and pipeline latency are also increased.
SingleThis is the default setting for data type precision.
Single coefficient, double computationThis mode offers a tradeoff between Single and Double modes of floating-point data type precision. To save memory usage, the coefficients that are stored in single. The matrix computations are then performed in double for improved accuracy.
Fixed-point

This mode of data type precision determines the dynamic range of state-space matrices, and computes the appropriate fraction lengths and full precision integer rounding modes by using the specified word length. This reduces resource utilization and improves FPGA sampling frequency by reducing the oversampling factor.

To learn more about the floating-point precision settings and tradeoffs, see Use Floating-Point Precision.

In digital hardware, numbers are represented using either fixed-point or floating-point data types. The dynamic range of fixed-point values is much less than that of floating-point values with the same word sizes. Therefore, fixed-point values must be scaled to avoid overflow or quantization errors. Floating-point processors simplify the real-time implementation of a control law or digital filter, with floating-point numbers closely approximating real-world numbers. On the other hand, microcontrollers or processors with fixed-point hardware have less complicated logic circuits, require less memory and processing time for calculations, and are more cost-effective. To learn more about how to decide on using fixed-point data types for your plant models, see Use Fixed-Point Precision.

Map State Space Parameters to RAMs

The Map state space parameters to RAMs setting enables you to map the state space parameters onto the hardware resources such as RAMs or lookup tables (LUTs).

Map State Space Parameters to RAMsDescription
Auto (default)Maps the state space parameters to RAMs when the number of modes exceeds a set threshold value (200). Otherwise, it maps them to LUTs.
OnMaps state space parameters to RAMs.
OffMaps state space parameters to LUTs.

Optimal Sharing Factor Supported FPGA Device Families

The Simscape HDL Workflow Advisor supports the optimal value of sharing factor for the following FPGA device families and parts listed in the table.

Device FamilyParts

Xilinx® Vivado®

Kintex®-7

xc7k325t

xc7k410t

Kintex U

xcku115-flvb1760-1-c

xcku085-flvb1760-1-c

Artix®-7

xc7a200t

xc7a50t

Zynq® UltraScale+™

xczu11eg-ffvc1760-2-e

xczu17eg-ffvc1760-2-e

xczu19eg-ffvc1760-2-e

Altera®

MAX® 10

10M50DAF484C6GES

Related Topics