Community Profile

photo

Fangjun Jiang


Last seen: Today 2011년부터 활동

What is a model? Professional Interests: Model-Based Development

Programming Languages:
MATLAB
Spoken Languages:
English
Pronouns:
He/him

통계

All
  • 36 Month Streak
  • Revival Level 3
  • First Review
  • Ace
  • Thankful Level 3
  • Knowledgeable Level 5
  • First Answer
  • Solver

배지 보기

Content Feed

보기 기준

답변 있음
How to read To Workspace block signal value to App Designer ?
Likely it is caused by this Signal1 = get_param('mymodel.slx/To Workspace1','VariableName') gives you a char array containing t...

대략 4시간 전 | 0

답변 있음
Stateflow while-logic dead loop
When input==1, you do have an infinite loop, right? Connecting the feedback transition to the bottom junction would resolve it....

대략 6시간 전 | 0

답변 있음
issues about zero_crossing_types.h during code generate
un-check the "Enable zero-crossing detection for fixed-step simulation" option in the Solver setting? Also, search for "zero-cr...

대략 7시간 전 | 0

| 수락됨

답변 있음
How to connect Inport Inport or Outport Outport programmatically
Yes. You can! I have done that using the add_line('connect_model','Constant/1','Gain/1') syntax by matching name. You are con...

대략 7시간 전 | 0

답변 있음
what is that blue block in Matlab is that a subsystem? what is the actual name of that block in Matlab?
It is called an "Area". On the left side of your Simulink canvas, click that "square" icon, below the "Image" icon.

대략 9시간 전 | 0

답변 있음
Signal name must resolve to Simulink signal object error
uncheck the 'Signal name must resolve to Simulink signal object' for the signal SC_*** the error goes away, like you did. Set S...

1일 전 | 0

답변 있음
Why is microservice able to load 'txt' files from subdirectory but not ".mat" files?
Notice the two backslashes "\\" in the error message about the file? "error":{"id":"MATLAB:load:couldNotReadFile","message":"Un...

1일 전 | 1

| 수락됨

답변 있음
Simulink Line connection error
You might need this "Ground" block. https://www.mathworks.com/help/simulink/slref/ground.html Not the "Ground" block from SimS...

1일 전 | 0

답변 있음
Add column in specific number range to available table
try this A.B(:,1) = randi([400,2970],[1650 1]) understand this. Generate a 3x1 matrix with random interger value that is betwe...

2일 전 | 0

답변 있음
How to apply App Designer output to Constant of simulink model ?
The workspace value is compiled/built for simulaiton only once when the model is initialized. It will not be updated to the mode...

2일 전 | 0

| 수락됨

답변 있음
Deal with Closed MATLAB Executable and Windows command line
Based on the error message, it seems that "input1" is passed to the app when you run it in command line my_app_name input1 inpu...

2일 전 | 0

답변 있음
sinusoidal elevation wave with time
Maybe this example gives you an idea? t=0:0.01:20; f1=1; y1=sin(2*pi*f1*t); f2=0.05; y2=sin(2*pi*f2*t); y0=y1.*y2; figure...

3일 전 | 0

답변 있음
How can I put an output from the display function in a table?
Create a table, fill the data and display it. doc table

3일 전 | 0

답변 있음
How to use integer or other datatype condition in if Block, Simulink?
Try this, Use a Relational Operator block where you can specify any data type for the inputs. Specify the output data type as bo...

4일 전 | 0

| 수락됨

답변 있음
i'm using bus selector block but once i add 4 or more signal, it is showing only one output.
Un-check the "Output as virtual bus" option at the dialog? https://www.mathworks.com/help/simulink/slref/busselector.html

7일 전 | 0

답변 있음
How do I change the properties of an Enum stored in a data dictionary programmatically?
Follow this? https://www.mathworks.com/help/simulink/ug/store-data-in-dictionary-programmatically.html

9일 전 | 0

| 수락됨

답변 있음
Simulink Solver Settings Doubt
You could do experiments to find out why. Use To Workspace block with -1 as sample time to log the inputs. Run simulation with d...

9일 전 | 0

답변 있음
error using mex function.
Follow this and make sure you got the correct version. https://www.mathworks.com/matlabcentral/answers/313298-i-already-have-mi...

10일 전 | 1

답변 있음
List all the ports of a subsystem and it's data types
This answer should also apply to a Subsystem block. https://www.mathworks.com/matlabcentral/answers/95626-how-do-i-query-the-da...

10일 전 | 0

질문


How to enforce guidelines regarding the use of Generative AI on MATLAB Answers forum?
First, I felt that the three answers provided by a user in this thread might have been generated by AI. How do you think? https...

13일 전 | 답변 수: 0 | 0

0

답변

답변 있음
in this simulation model, how can i resolve the shown error, due to capacitor (shown the parameters)
In the error message, the variable 'v' refers to the parameter voltage under "Initial Targets". It seems like you need to check ...

14일 전 | 0

답변 있음
Calculation of RMS like dc signal for a sinusoidal signal using Simulink algorithm
The RMS Measurement block? https://www.mathworks.com/help/sps/ref/rmsmeasurement.html

14일 전 | 0

답변 있음
How to set and get value for a Data Store Memory.
See if this helps. https://www.mathworks.com/help/simulink/ug/using-global-data-with-the-matlab-function-block.html

15일 전 | 0

| 수락됨

답변 있음
Use an 'auto' variable from the script in the matlab to simulink solver
Yes. This is a problem. A Mathworker might be able to explain why it is done this way. I can provide a workaround solution. In ...

15일 전 | 1

| 수락됨

답변 있음
How to load justification file in Model advisor, Matlab R2022b?
For R2022b, it's here. https://www.mathworks.com/help/releases/R2022b/slcheck/ug/_mw_584cd3da-fd76-45a5-9459-0edc715a08e6.html

17일 전 | 0

답변 있음
get_param(confgset, 'SampleTime') does not return any value...
Your lucky guess stopped at three. It is not called 'SampleTime'. You are probably looking for 'MaxStep'. https://www.mathwork...

20일 전 | 0

| 수락됨

답변 있음
How to plot from a specific point?
Use line(), you need to put the data in the right format. See help document Vector=[20;50;0]; Traslacion=[10;-15;10]; d=[Tras...

21일 전 | 0

답변 있음
How to turn off and turn on PWM signal?
Generate the PWM signal that is always on. Its period or width could all change as needed. Generate another pulse signal. This ...

22일 전 | 0

답변 있음
Function Trigger as input to sub-system to be simulated via MIL Testing (spreadsheet)
Function trigger (Function-Call) can be fed to a subsystem. It does not matter whether the simulation is MIL, SIL or HIL. It doe...

22일 전 | 0

더 보기