답변 있음
How to make SimMechanics works in rapid accelerator mode
In Model Settings (or Ctrl+E) - Simscape - Data Logging: turn Log Simulation Data to "None".

6달 전 | 0

답변 있음
Joint Actuation Inputs: Specify both Motion and Force/Torque
Hi Nicholas, It is possible to specify EITHER motion OR force as "provided by input", but not both. Specifying both is physica...

6달 전 | 0

답변 있음
How can I view the convex hull geometry exported from a file solid block in simscape multibody?
If you have a way to convert the STEP file into STL, I know of a way to do this outside Multibody using MATLAB command convhull ...

6달 전 | 0

답변 있음
Temperature control of furnace model
Hope it's not too late ... It looks like the Furnance block is set up such that it produces (1) a burning temperature in the H...

6달 전 | 0

답변 있음
Centrifugal Pump (IL) Predefined Parameterization
This feature is available starting 2020b. The list of predefined pumps is growing but it may not include the exact one you want...

6달 전 | 1

| 수락됨

답변 있음
Control the pressure AND the mass flow rate of a pipeflow in Simscape
Looks like you were trying to set the outlet pressure of the pipe by adjusting the orifice parameters. It's definitely reasonab...

6달 전 | 0

| 수락됨

답변 있음
How to obtain the saturated vapor or liquid temperature from the simscape component: Condenser-Evaporator (TL-2P) during simulation?
In the latest release (R2021a), the 2P domain in the foundation library contains a Saturation Property Sesnsor that would allow ...

6달 전 | 0

답변 있음
Revolute joint in Simscape
I hope I understood your question correctly that you are trying to attach two revolute joints in different orientations to one s...

6달 전 | 0

| 수락됨

답변 있음
Simcape two phase fluid custom component
The convection_A & convection_B are two components that defines the behavior at the "port" or boundary of this block. If you lo...

6달 전 | 0

| 수락됨

답변 있음
How can I program a installer chamber in Simscape?
It would be helpful if you could include some diagram or sketch to show what you want to model. My best guess based on what yo...

6달 전 | 0

답변 있음
how to make an oscillating guide on simscape
This looks (almost) exactly like this example: https://www.mathworks.com/help/releases/R2021a/physmod/sm/ug/how-to-build-a-mode...

6달 전 | 0

| 수락됨

답변 있음
regarding thermal liquid reservoir TL
I think this depends on what question you would like to answer with your model. If you just want to study the heat transfer a...

6달 전 | 0

답변 있음
4 way 2 position directional control valve in simscape fluid
There are multiple physical domains that have 4-way valve blocks, so it's not clear from your question which specific domain/blo...

6달 전 | 0

답변 있음
How to get the attitude data of the UAV in simscape ?
I believe the most convenient way of measuring the position and orientation of a solid block is to use a transform sensor. It g...

6달 전 | 0

답변 있음
Issue with simHydraulic and double-acting hydraulic actuator
Sounds like the question is resolved. Will paste the comments here: Yifeng Tang Hi Thomas, Looks like you are using a much...

약 1년 전 | 0

| 수락됨

답변 있음
Simscape parameters restricted to a list? Changing the underlying model of a component from a dropdown list ?
I think the easiest way to do the first task is to define a "mask" around the component. It's fairly easy to edit the mask and ...

약 1년 전 | 0

답변 있음
Can Simscape domains be defined with vectors?
Yes. It's possible. I wonder where you find the quoted code, because I've been using [0;0;0] format not knowing it's OK the ot...

약 1년 전 | 0

답변 있음
In Simscape Rankine Cycle example the Turbine does not rotate
Hi Marlon, I tried to modify the example the way you showed in the screenshot. The model had difficulty initializing and won't...

약 1년 전 | 0

| 수락됨

답변 있음
Non-physical unlimited negative pressure results in Fixed Displacement Pump/Motor
Hi Itay, I believe this has to do with the fact that the A port of the pump is connected to a "cap", with no volume. If you co...

약 1년 전 | 0

답변 있음
Simscape Fluids Fixed-Displacement Motor Issues
Hey Trevor, I know this may be too late for your competition. But what I noticed in your model is that the fixed-displacement ...

약 1년 전 | 0

답변 있음
Control of Ball valve
Hi Ankith, I looked at your model and connected an sine wave signal/command to the valve actuator block. The ball valve seems ...

약 1년 전 | 0

답변 있음
How to access Hydraulic Power value from Pump block?
Hi Lucca, The Probe right now only works with quantities that is visible in the "variables" tab of the block, so you are right ...

약 1년 전 | 0

| 수락됨

답변 있음
Simulink Design Optimization toolbox: Estimate parameters using several experiment data
Hi Kouta, One solution I can think of: Make three copies of your model, in one same Simulink model, all use the same parameter...

약 1년 전 | 0

답변 있음
Is there any plan in the work to create a 2P-TL Heat Exchanger block for simscape?
There is a prototype of (2P-TL) heat exchanger in R2019b & R2020a. Please work with your MathWorks sales or contact the Custome...

약 1년 전 | 0

답변 있음
Is it possible to include NIST DATABASE to Simscape Fluids to calculate with different Fluids (specialy gas) and mixtures of fluids?
Hi Thomas, I believe the best option is to use "twoPhaseFluidTables" function to generate fluid property tables from REFPROP (f...

약 1년 전 | 0