답변 있음
Can anyone help me to solve this error?
Dear Shankarao Rajasuriyan It is occur due to Numbers of signal input in the multiplication/division block After Mux block t...

거의 3년 전 | 0

답변 있음
Why MATLAB crashed while running PV based boost converter simulink model
Dear, This kind of problem rarely occurs. And it occurs due to improper design of system parameters ( Such as inductive or Cap...

거의 3년 전 | 0

| 수락됨

답변 있음
Stator Flux Estimation of Induction Motor in real time
If any one suffer with above problems It is occurring due to DC ofset in sensed quantity ( it is due to sensor's inherently pro...

거의 3년 전 | 0

| 수락됨

답변 있음
can't connect source generator with controlled voltage source in matlab simulink
Both elements belong to different libraries. to connect both of them please use simulink to physical connector as attached fil...

거의 3년 전 | 1

| 수락됨

질문


Data Plotting in a Single Figure
Dear all, I want to plot a single figure including four variable. I have a data as atteched file I want to plot a figure i...

대략 3년 전 | 답변 수: 1 | 0

1

답변

질문


Stator Flux Estimation of Induction Motor in real time
Hi, I am using TMS320F28379D LAUNCHPad for implementation of induction motor control and code is generated from MATLAB2019b. f...

3년 초과 전 | 답변 수: 1 | 1

1

답변

답변 있음
What is wrong with my matlab codes? ( MATLAB) please help me!
Please replace the all * with .* for element wise product and in line no 31, you neet to replace t with wt

3년 초과 전 | 0

| 수락됨

질문


Higher Order (6X6) Matrix Inverse with Variables
Hi, I want to obtained Inverse of higher order (6X6) matrix via matlab Matrix Like This Is it possible to obtained inverse...

3년 초과 전 | 답변 수: 1 | 0

1

답변

답변 있음
Error: "Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks..."
Dear, You have to recuired Solver Configuration block at grounding point as shown in attached file the Solver Configuration ...

3년 초과 전 | 2

답변 있음
I want to model 100KVA load operating at 0.9 power factor lagging. What should i set Active Power, QL and QC in load parameters?
Dear Syed Umaid Ali, as per your requirement Apparent power S= √(P^2+Q^2 ).....................................(1) And power...

3년 초과 전 | 0

| 수락됨

질문


Figure plote in MATLAB 2019b
Hi, I am ploting the figure on matlab 2019b in sub plot formate(more than one plote in single figure), whenever i set the possi...

3년 초과 전 | 답변 수: 1 | 0

1

답변

답변 있음
Warning: Matrix is close to singular or badly scaled ( simulink model with simscape blocks simpowersystems)
Dear Sreeraj This kind of error is occure whenever your simulink model having denomenator zero, If you are using for code genr...

3년 초과 전 | 0

답변 있음
TI C2000 ADC Output
Dear Bilal Ahmad, The observed, scope signal is differ from actual signal that means your actual signal is 400Hz frequancy but ...

대략 4년 전 | 0

답변 있음
How to obtain the rotor side and grid side control of GRID connected DFIG based wind energy conversion system
Dear Sri Lakshmi, To devoloped control for DFIG based grid connected wind energy conversion system (WECS), please analysis as ...

대략 4년 전 | 0

답변 있음
how can I overcome on algebraic loop in simulink
Dear, Rashed, Basialy algebric loop error occure in simulink model whenever zero is come in denomenator part of any function. ...

대략 4년 전 | 1

| 수락됨

답변 있음
Power input fluctuating causes?
Power extraction from PV is dependent on controller. Actualy your inverter controller is responible to trac the MPPT, because ...

대략 4년 전 | 0

질문


TMS320F28379D: Using MATLAB2018a to observed analog signal from DACOUTB pin
Hi, I am using hardware targate suport pakage for TIC2000, to implement control techniques on TMS320F28379D from MATLAB simulin...

대략 4년 전 | 답변 수: 0 | 0

0

답변

답변 있음
How to open 2019b simulink models in 2019a version??
Dear, Dileepa B. S, For open to simulink model in MATLAB2019a, wchich is created in MATLAB2019b, For this, you can take help ...

대략 4년 전 | 0

답변 있음
voltage regulator design for solar under varying irradiance
Dear Josh, To maintan the output dc voltage constant with resistive load you have to required PI controller. with resistive l...

4년 초과 전 | 0

답변 있음
TMS320F28335: Simulink generates code automatically
Dear Min, For This, You have to required Two sumulation model, first one is control model and second one is host model. For ...

4년 초과 전 | 0

답변 있음
TMS320F28335: Simulink generates code automatically
Dear Big Min, For DSP kit(TMC320F28335) interfacinng with matlab, You need to do following steps:- Go to the add on and add...

4년 초과 전 | 0

| 수락됨

질문


Implementation of real time close loop control on TMS320F28379D dsp controller using MATLAB Simulation
Hi, I am working on implementation of real time close loop control on dsp TMS320F28379D, for synchronization of voltage source...

4년 초과 전 | 답변 수: 1 | 1

1

답변

답변 있음
I AM NOT ABLE TO INTERFACE TMS320F28379D
Dear Aratrika, For DSP kit(TMC320F28379D) interfacinng with matlab 12018a. You need to do following steps:- Go to the add on...

4년 초과 전 | 0

| 수락됨

답변 있음
External mode error 28379D
I have same problem in close loop operation of VSI when PI controller is used from discrete library. I think as per your model ...

4년 초과 전 | 0

질문


Fuzzy Based MPPT Development
Dear sir/madam, I want to devoloped Fuzzy logic based mppt, after devoloping the rulse, here two input and one output, this is ...

대략 5년 전 | 답변 수: 0 | 0

0

답변

질문


The target PC 1 is not connecting for real time simulation, what is the solution for it?
Dear sir/Mam, I'm having trouble for conecting PC 1 on real time explorer, ### Simulink Real-Time Test Suite ### Host-Targe...

5년 초과 전 | 답변 수: 1 | 0

1

답변

질문


i have problem while interface matlab 2015a with c2000 piccolo launchpad F-28027F and using ccs6v.
Respected sir/mam please provide me solution, i have problem while interface matlab 2015a with c2000 piccolo launchpad F-2802...

5년 초과 전 | 답변 수: 0 | 0

0

답변