Cascade filters and amplify
조회 수: 5 (최근 30일)
이전 댓글 표시
Hi
I don’t have much experience in MATLAB but I have a circuit that amplifies low frequency breathing it consists of four op-amps each amplify by 10 and each have a second order bandpass set to .1Hz to .4Hz.
I have now used one op-amp as above and a 24bit ADC sampling at 100Hz and my number of samples is 6000 (60 Seconds of data)
I have managed to bring the data in to MATLAB (please see attached) but I am struggling to implement the filters and gain could somebody please assist me.
Many thanks in anticipation
Kind Regards
David
댓글 수: 0
채택된 답변
Mathieu NOE
2021년 6월 24일
Here you are my friend
the demo is done on a second order bandpass Butterworth filter ; you ca simply increase the order to match was was done in your analog filters
hope it helps
all the best ,
clearvars
load('Raw_Data.mat');
Fs = sample_rate;
samples = number_of_samples;
x = raw_ad_data_sine;
dt = 1/Fs;
t = (0:samples-1)'*dt;
% IIr filter : bandpass butterworth
order = 2;
[numd,dend] = butter(order,2/Fs*[0.1 0.4]);
figure(1)
dbode(numd,dend,dt); % bode plot
y = filtfilt(numd,dend,x); % Zero-phase forward and reverse digital IIR filtering.
figure(2) % time plot
plot(t,x,t,y);