Target with Windows 7 using Simulink Real-Time

조회 수: 2 (최근 30일)
Jose Briceño
Jose Briceño 2018년 8월 23일
편집: Stefanie Schwarz 2021년 12월 8일
I'm trying to connect a host computer via ethernet card using this code: tg = slrt; getPCIInfo(tg, 'ethernet')
But it's not working, I get this error:
Error using SimulinkRealTime.target>getAppObjFromTargetSettings
Enter a valid target address for TargetPC1
Error in SimulinkRealTime.target
Error in slrt (line 18) obj = SimulinkRealTime.target(varargin{:});
In my host computer I have windows 10 and in my target I have windows 7. The target computer must have any program installed?

채택된 답변

Diego Kuratli
Diego Kuratli 2018년 8월 26일
The target requires Simulink Real-Time kernel (which is typically loaded from DOS environment, not Windows). If you are using Speedgoat systems, the target machine is already configured with all required software components, ready to use.
  댓글 수: 2
Jose Briceño
Jose Briceño 2018년 8월 26일
Thanks, And how can I put the Simulink Real-Time kernel in my target computer. I'm not using a Speedgoat system.
Diego Kuratli
Diego Kuratli 2018년 8월 26일
Simulink Real-Time is designed to work with Speedgoat systems. Third-party hardware is no longer supported.

댓글을 달려면 로그인하십시오.