- Verify that the FMU simulates without any errors or issues in the third-party that was used to create it.
- In the FMU block, select the Enable FMU Debug Logging checkbox in the 'Simulation' tab to see a more descriptive error.

- The following “Advanced” diagnostic parameter prevents a MATLAB crash (“out-of-process mode”) in some cases:

- Use the FMU Compliance checker. This tool can help determine if the issue stems from the generated FMU not adhering to standards (i.e. an issue from a third-party tool) or with MathWorks tools. https://github.com/modelica-tools/FMUComplianceChecker/releases
- Check that the “Communication step size” is compatible with the model: https://www.mathworks.com/help/simulink/ug/implement-an-fmi-block.html#mw_f1a9abe7-d7ed-4696-8c46-42c72d74ba83
How do I troubleshoot FMU Import issues in Simulink?
조회 수: 28 (최근 30일)
이전 댓글 표시
MathWorks Support Team
2022년 11월 14일
편집: MathWorks Support Team
2023년 6월 6일
I am using an FMU block to import a third-party functionality into Simulink. I run into errors or MATLAB crashes during the import workflow. How can I debug FMU import issues in Simulink?
채택된 답변
MathWorks Support Team
2023년 6월 6일
Imported FMUs in Simulink can cause failures for different reasons. Here are some common troubleshooting tips that will help in the debug process: