Clear a persistent variable in a MATLAB Fcn block as serial object
조회 수: 4 (최근 30일)
이전 댓글 표시
Hello! I am using following code for read data from serial port:
function y = fcn(u)
coder.extrinsic('only3')
coder.extrinsic('strncmp')
coder.extrinsic('serial', 'fopen','fread')
coder.extrinsic('get')
persistent s a b
y = uint8(zeros(2,1)); %signal is an uint8
if isempty(s)
% only do this the first time
s = serial('COM12','Terminator','', 'InputBufferSize', 1024);
a = '000';
b = false;
a = only3(get(s,'status'));
b = strncmp(a,'clo',3);
switch double(b)
case 1
fopen(s);
otherwise
fclose(s);
end
end
y = uint8(fread(s,[2 1],'uint8'));
Where 'only3' is my function that takes only the first 3 chars from a string. The problem is that communication does not terminate with simulation stopping. Switch case has no effect (I thought that it shuts down reading after an other run). How can I clear persistent variable 's' and reset the block after stopping?
댓글 수: 0
답변 (3개)
Friedrich
2014년 2월 27일
편집: Friedrich
2014년 2월 27일
Hi,
A MATLAB FCN Block is a bad idea here. Better would be a MATLAB LVL 2 S-function because you can better control your serial port. In the mdlStart you create your serial object and later in the mdlTerminate you close it propperly. In the mdlOutputs you calculate the signal as usual.
댓글 수: 6
Friedrich
2014년 3월 3일
Yes. You open the serial port in the mdlInitializeSizes and close it in the mdlTerminate.
Ryan Livingston
2014년 4월 2일
Another thought could be to use the serial port I/O blocks directly in Simulink. See the Blocks heading here:
I am not too familiar with them, but they may facilitate a simpler interface to your hardware.
These could perform the I/O and then you could process the data using the method of your choosing.