Main Content

Photodiode

Photodiode with incident flux input port

  • Photodiode block

Libraries:
Simscape / Electrical / Sensors & Transducers

Description

The Photodiode block represents a photodiode as a controlled current source and an exponential diode connected in parallel. The controlled current source produces a current Ip that is proportional to the radiant flux density:

Ip = DeviceSensitivity · RadiantFluxDensity(1)

where:

  • DeviceSensitivity is the ratio of the current produced to the incident radiant flux density.

    • If you select Specify measured current for given flux density for the Sensitivity parameterization parameter, the block calculates this variable by converting the Measured current parameter value to units of amps and dividing it by the Flux density parameter values.

    • If you select Specify current per unit flux density for the Sensitivity parameterization parameter, this variable is defined by the Device sensitivity parameter value.

  • RadiantFluxDensity is the incident radiant flux density.

To model dynamic response time, use the Parameterization parameter in the Junction capacitance tab to include the diode junction capacitance in the model.

The exponential diode model provides the following relationship between the diode current I and the diode voltage V:

I=IS(eqVNkTm11)

where:

  • q is the elementary charge on an electron (1.602176e–19 Coulombs).

  • k is the Boltzmann constant (1.3806503e–23 J/K).

  • N is the emission coefficient.

  • IS is the saturation current, which is equal to the Dark current parameter value.

  • Tm1 is the temperature at which the diode parameters are specified, as defined by the Measurement temperature parameter value.

When (qV / NkTm1) > 80, the block replaces eqVNkTm1 with (qV / NkTm1 – 79)e80, which matches the gradient of the diode current at (qV / NkTm1) = 80 and extrapolates linearly. When (qV / NkTm1) < –79, the block replaces eqVNkTm1 with (qV / NkTm1 + 80)e–79, which also matches the gradient and extrapolates linearly. Typical electrical circuits do not reach these extreme values. The block provides this linear extrapolation to help convergence when solving for the constraints during simulation.

When you select Use dark current and N for the Diode parameterization parameter, you specify the diode in terms of the Dark current and Emission coefficient N parameters. When you select Use dark current plus a forward bias I-V data point for the Diode parameterization parameter, you specify the Dark current parameter and a voltage and current measurement point on the diode I-V curve. The block calculates N from these values as follows:

N=VF/(Vtlog(IF/IS+1))

where:

  • VF is the Forward voltage VF parameter value.

  • Vt = kTm1 / q.

  • IF is the Current IF at forward voltage VF parameter value.

The exponential diode model provides the option to include a junction capacitance:

  • When you select Fixed or zero junction capacitance for the Parameterization parameter, the capacitance is fixed.

  • When you select Use parameters CJO, VJ, M & FC for the Parameterization parameter, the block uses the coefficients CJO, VJ, M, and FC to calculate a junction capacitance that depends on the junction voltage.

  • When you select Use C-V curve data points for the Parameterization parameter, the block uses three capacitance values on the C-V capacitance curve to estimate CJO, VJ, and M and uses these values with the specified value of FC to calculate a junction capacitance that depends on the junction voltage. The block calculates CJO, VJ, and M as follows:

    • CJ0=C1((VR2VR1)/(VR2VR1(C2/C1)1/M))M

    • VJ=(VR2(C1/C2)1/M+VR1)/(1(C1/C2)1/M)

    • M=log(C3/C2)/log(VR2/VR3)

    where:

    • VR1, VR2, and VR3 are the values in the Reverse bias voltages [VR1 VR2 VR3] vector.

    • C1, C2, and C3 are the values in the Corresponding capacitances [C1 C2 C3] vector.

    It is not possible to estimate FC reliably from tabulated data, so you must specify its value using the Capacitance coefficient FC parameter. In the absence of suitable data for this parameter, use a typical value of 0.5.

    The reverse bias voltages (defined as positive values) should satisfy VR3 > VR2 > VR1. This means that the capacitances should satisfy C1 > C2 > C3 as reverse bias widens the depletion region and hence reduces capacitance. Violating these inequalities results in an error. Voltages VR2 and VR3 should be well away from the Junction potential VJ. Voltage VR1 should be less than the Junction potential VJ, with a typical value for VR1 being 0.1 V.

The voltage-dependent junction is defined in terms of the charge of junction capacitance Qj as:

  • For V < FC·VJ:

    Qj=CJ0(VJ/(M1))((1V/VJ)1M1)

  • For VFC·VJ:

    Qj=CJ0F1+(CJ0/F2)(F3(VFCVJ)+0.5(M/VJ)(V2(FCVJ)2))

where:

  • F1=(VJ/(1M))(1(1FC)1M))

  • F2=(1FC)1+M))

  • F3=1FC(1+M)

  • V is the junction capacitance voltage.

These equations are the same as used in [2], except that the temperature dependence of VJ and FC is not modeled. This model does not include the diffusion capacitance term that affects performance for high frequency switching applications.

The Photodiode block contains several options for modeling the dependence of the diode current-voltage relationship on the temperature during simulation. Temperature dependence of the junction capacitance is not modeled, this being a much smaller effect. For details, see the Diode reference page.

Thermal Port

You can expose the thermal port to model the effects of generated heat and device temperature. To expose the thermal port, set the Modeling option parameter to either:

  • No thermal port — The block does not contain a thermal port and does not simulate heat generation in the device.

  • Show thermal port — The block contains a thermal port that allows you to model the heat that conduction losses generate. For numerical efficiency, the thermal state does not affect the electrical behavior of the block.

For more information on using thermal ports and on the Thermal Port parameters, see Simulating Thermal Effects in Semiconductors.

Variables

To set the priority and initial target values for the block variables before simulation, use the Initial Targets section in the block dialog box or Property Inspector. For more information, see Set Priority and Initial Target for Block Variables.

Note

To satisfy all your initial targets, do not set the priority to High for more initial targets than the total number of differential variables in the block equations.

  • If in the Capacitance section, you set Parameterization to Fixed or zero junction capacitance and Junction capacitance to 0, the total number of differential variables in the block equations is zero. Do not set the priority of any variables in the Initial Targets section to High.

  • If in the Capacitance section, you set Parameterization to Fixed or zero junction capacitance and you set the Junction capacitance parameter to a nonzero value, the total number of differential variables in the block equations is one. Set the priority to High for no more than one variable in the Initial Targets section.

  • If in the Capacitance section, you set Parameterization to Use C-V curve data points or Use parameters Cj0, VJ, M & FC, the total number of differential variables in the block equations is one. Set the priority to High for no more than one variable in the Initial Targets section.

Use nominal values to specify the expected magnitude of a variable in a model. Using system scaling based on nominal values increases the simulation robustness. Nominal values can come from different sources. One of these sources is the Nominal Values section in the block dialog box or Property Inspector. For more information, see System Scaling by Nominal Values.

Plot Basic I-V Characteristics

You can plot the basic I-V characteristics of the Photodiode block without building a complete model. Use the plots to explore the impact of your parameter choices on device characteristics. If you parameterize the block from a datasheet, you can compare your plots to the datasheet to check that you parameterized the block correctly. If you have a complete working model but do not know which manufactured part to use, you can compare your plots to datasheets to help you decide.

To enable this option, set the Modeling option parameter of the Photodiode block to No thermal port. To plot the basic characteristics, right-click the block and select Electrical > Basic characteristics from the context menu. For more information about the Basic characteristics option, see Plot Basic I-V Characteristics of Semiconductor Blocks.

Assumptions and Limitations

  • When you select Use dark current plus a forward bias I-V curve data point for the Diode parameterization parameter, choose a voltage near the diode turn-on voltage. Typically this will be in the range from 0.05 to 1 Volt. Using a value outside of this region may lead to a poor estimate for N.

  • You may need to use nonzero ohmic resistance and junction capacitance values to prevent numerical simulation issues, but the simulation may run faster with these values set to zero.

Ports

Output

expand all

Physical signal port associated with the incident flux.

Conserving

expand all

Electrical conserving port associated with the anode.

Electrical conserving port associated with the cathode.

Thermal conserving port.

Dependencies

To enable this port, set Modeling option to Show thermal port.

Parameters

expand all

Whether to enable the thermal port of the block and model the effects of generated heat and device temperature.

Main

Select one of the following methods for sensitivity parameterization:

  • Specify measured current for given flux density — Specify the measured current and the corresponding flux density. This is the default method.

  • Specify current per unit flux density — Specify the device sensitivity directly.

The current the block uses to calculate the device sensitivity.

Dependencies

This parameter is visible only when you select Specify measured current for given flux density for the Sensitivity parameterization parameter.

The flux density the block uses to calculate the device sensitivity.

Dependencies

This parameter is visible only when you select Specify measured current for given flux density for the Sensitivity parameterization parameter.

The current per unit flux density.

Dependencies

This parameter is visible only when you select Specify current per unit flux density for the Sensitivity parameterization parameter.

Select one of the following methods for diode model parameterization:

  • Use dark current plus a forward bias I-V data point — Specify the dark current and a point on the diode I-V curve. This is the default method.

  • Use dark current and N — Specify dark current and emission coefficient.

The current at the forward-biased point on the diode I-V curve that the block uses to calculate IS and N.

Dependencies

This parameter is visible only when you select Use dark current plus a forward bias I-V data point for the Diode parameterization parameter.

The corresponding voltage at the forward-biased point on the diode I-V curve that the block uses to calculate IS and N.

Dependencies

This parameter is visible only when you select Use dark current plus a forward bias I-V data point for the Diode parameterization parameter.

The current through the diode when it is not exposed to light.

The diode emission coefficient or ideality factor.

Dependencies

This parameter is visible only when you select Use dark current and N for the Diode parameterization parameter.

The series diode connection resistance.

The temperature at which the I-V curve or dark current was measured.

Junction Capacitance

Select one of the following options for modeling the junction capacitance:

  • Fixed or zero junction capacitance — Model the junction capacitance as a fixed value.

  • Use C-V curve data points — Specify measured data at three points on the diode C-V curve.

  • Use parameters CJ0, VJ, M & FC — Specify zero-bias junction capacitance, junction potential, grading coefficient, and forward-bias depletion capacitance coefficient.

Fixed value of the junction capacitance.

Dependencies

This parameter is visible only when you select Fixed or zero junction capacitance for the Parameterization parameter.

Value of the capacitance placed in parallel with the exponential diode term.

Dependencies

This parameter is visible only when you select Use parameters CJ0, VJ, M & FC for the Parameterization parameter.

A vector of the reverse bias voltage values at the three points on the diode C-V curve that the block uses to calculate CJ0, VJ, and M.

Dependencies

This parameter is visible only when you select Use C-V curve data points for the Parameterization parameter.

A vector of the capacitance values at the three points on the diode C-V curve that the block uses to calculate CJ0, VJ, and M.

Dependencies

This parameter is visible only when you select Use C-V curve data points for the Parameterization parameter.

Junction potential.

Dependencies

This parameter is visible only when you select Use parameters CJ0, VJ, M & FC for the Parameterization parameter.

The grading coefficient.

Dependencies

This parameter is visible only when you select Use parameters CJ0, VJ, M & FC for the Parameterization parameter.

Fitting coefficient that quantifies the decrease of the depletion capacitance with applied voltage.

Dependencies

This parameter is visible only when you select Use C-V curve data points or Use parameters CJ0, VJ, M & FC for the Parameterization parameter.

Temperature Dependence

Select one of the following methods for temperature dependence parameterization:

  • None — Simulate at parameter measurement temperature — Temperature dependence is not modeled, or the model is simulated at the measurement temperature Tm1 (as specified by the Measurement temperature parameter on the Main tab). This is the default method.

  • Use an I-V data point at second measurement temperature T2 — If you select this option, you specify a second measurement temperature Tm2, and the current and voltage values at this temperature. The model uses these values, along with the parameter values at the first measurement temperature Tm1, to calculate the energy gap value.

  • Specify saturation current at second measurement temperature T2 — If you select this option, you specify a second measurement temperature Tm2, and saturation current value at this temperature. The model uses these values, along with the parameter values at the first measurement temperature Tm1, to calculate the energy gap value.

  • Specify the energy gap EG — Specify the energy gap value directly.

Specify the diode current I1 value when the voltage is V1 at the second measurement temperature.

Dependencies

This parameter is visible only when you select Use an I-V data point at second measurement temperature T2 for the Parameterization parameter.

Specify the diode voltage V1 value when the current is I1 at the second measurement temperature.

Dependencies

This parameter is visible only when you select Use an I-V data point at second measurement temperature T2 for the Parameterization parameter.

Specify the saturation current IS value at the second measurement temperature.

Dependencies

This parameter is visible only when you select Specify saturation current at second measurement temperature T2 for the Parameterization parameter.

Specify the value for the second measurement temperature.

Dependencies

This parameter is visible only when you select Use an I-V data point at second measurement temperature T2 or Specify saturation current at second measurement temperature T2 for the Parameterization parameter.

Select a value for the energy gap from a list of predetermined options, or specify a custom value:

  • Use nominal value for silicon (EG=1.11eV) — This is the default.

  • Use nominal value for 4H-SiC silicon carbide (EG=3.23eV)

  • Use nominal value for 6H-SiC silicon carbide (EG=3.00eV)

  • Use nominal value for germanium (EG=0.67eV)

  • Use nominal value for gallium arsenide (EG=1.43eV)

  • Use nominal value for selenium (EG=1.74eV)

  • Use nominal value for Schottky barrier diodes (EG=0.69eV)

  • Specify a custom value — If you select this option, the Energy gap, EG parameter appears in the dialog box, to let you specify a custom value for EG.

Dependencies

This parameter is visible only when you select Specify the energy gap EG for the Parameterization parameter.

Specify a custom value for the energy gap, EG.

Dependencies

This parameter is visible only when you select Specify a custom value for the Energy gap parameterization parameter.

Select one of the following options to specify the saturation current temperature exponent value:

  • Use nominal value for pn-junction diode (XTI=3) — This is the default.

  • Use nominal value for Schottky barrier diode (XTI=2)

  • Specify a custom value — If you select this option, the Saturation current temperature exponent, XTI parameter appears in the dialog box, to let you specify a custom value for XTI.

Specify a custom value for the saturation current temperature exponent, XTI.

Dependencies

This parameter is visible only when you select Specify a custom value for the Saturation current temperature exponent parameterization parameter.

Specify the value for the temperature Ts, at which the device is to be simulated.

References

[1] H. Ahmed and P.J. Spreadbury. Analogue and digital electronics for engineers. 2nd Edition, Cambridge University Press, 1984.

[2] G. Massobrio and P. Antognetti. Semiconductor Device Modeling with SPICE. 2nd Edition, McGraw-Hill, 1993.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History

Introduced in R2008a

expand all