Main Content

Power Window

Automobiles use electronics for control operations such as:

  • Opening and closing windows and sunroof

  • Adjusting mirrors and headlights

  • Locking and unlocking doors

These systems are subject to stringent operation constraints. Failures can cause dangerous and possibly life-threatening situations. As a result, careful design and analysis are needed before deployment.

This example focuses on the design of a power window system of an automobile, in particular, the passenger-side window. A critical aspect of this system is that it cannot exert a force of more than 100 N on an object when the window closes. When the system detects such an object, it must lower the window by about 10 cm.

As part of the design process, the example considers:

  • Quantitative requirements for the window control system, such as timing and force requirements

  • System requirements, captured in activity diagrams

  • Data definitions for the signals used in activity diagrams

Other aspects of the design process that this example contains are:

  • Managing the components of the system

  • Building the model

  • Validating the results of system simulation

  • Generating code

MATLAB® and Simulink® support Model-Based Design for embedded control design, from initial specification to code generation. The power window control project shows how you can use MathWorks® tools and the Model-Based Design process to go from concept through implementation for an automobile power window system. It uses projects to organize the files and other model components.

Power Window Control Project

This example shows how to use a project to model a power window system for an automobile. The project uses Model-Based Design and these large-scale modeling techniques.

  • Model blocks to separate the hierarchy into separate models.

  • Variant Subsystems blocks to model and switch between different design choices.

  • Libraries to capture algorithms for reuse in variant subsystems.

  • Projects to manage the files required for the system development.

Design Requirements

In this example, consider the passenger-side power window system of an automobile. This system can never exert a force of more than 100 N on an object when closing the window.

When the model detects such an object, the model must lower the window by about 10 centimeters.

For more information on the design requirements, see Power Window.

Explore the Project

Upon visual inspection of the project, you can see features used to organize the example. These features are used to organize the project:

  • Folders

  • File Classification

  • Shortcuts

Folders

The project is organized into these folders:

  • configureModel - MATLAB® files that control the main system model variant configuration

  • data - Images required by the project

  • hmi - Files that animate the power window response

  • model - Main system model, controller model, models for testing the controller, and libraries that support these models

  • task - MATLAB files that simulate the model for the different model configurations and generate coverage reports for the controller

  • utilities - MATLAB files to initialize the model, to generate spreadsheet input, to add data to the generated spreadsheet, and manage the project environment at startup and shutdown

File Classification

Files in Projects have different classifications visible in the Labels pane. Each label describes the specific role a file contributes to the body of the project.

  • Configuration - Files that configure the project or model.

  • PrjConfig - Files that configure the project by adding its files to the path at startup and removing them at shutdown

  • DesignConfig - Files that determine which model configuration is active at a given time

  • Design - Main system model and its referenced control model

  • DesignSupport - Files such as libraries, data, and model simulation

  • Simulation - Files that simulate the model for a specific configuration

  • Test - Control coverage, the control interaction, and the test harness models

  • Visualization - Files that animate the motion of the power window

Shortcuts

Project shortcuts provide quick access to project files that are used most often. Some shortcuts contain general tasks, such as adding the project to the path at startup and removing it at shutdown. In addition, project shortcut groups help organize the shortcuts.

  • Interactive Testing - Files used for interactive testing of the controller

  • Main Model - File for top-level Simulink model

  • Model Coverage - Files used for model coverage of the controller

  • Simulation - Files used for simulation of model variant configurations

Explore Simulink Models in Project

The Simulink models for this project are located in the model folder.

  • Main System Model

  • Models for Testing

Main System Model

The main system model is slexPowerWindowExample. This model consists of driver_switch and passenger_switch subsystem blocks, which generate the inputs to the power_window_control_system block. The power_window_control_system block validates the states of the passenger and driver inputs. This block also determines if obstacle is blocking the path of the window. The referenced controller produces the window motion command signals sent to the active variant of the window system. The window_system block output is the feedback to the control system block.

To visualize the results of simulation, the Simulation Data Inspector logs the output data and Simulink 3D Animation™ animates the motion of the window.

Model Variants

The main system model in this project uses Variant Subsystem blocks to allow for multiple implementations within a subsystem. You can change the active implementation programmatically prior to simulation. The main model contains four Variant Subsystem blocks, each with variant choices that can be programmatically modified. Those four variant subsystems are:

  • slexPowerWindowExample/driver_switch

  • slexPowerWindowExample/passenger_switch

  • slexPowerWindowExample/window_system

  • slexPowerWindowExample/power_window_control_system/detect_obstacle_endstop

Each variant choice is associated with a variant control. The variant choice is active when its variant control evaluates to true.

You can control the combinations of variant choices to create model variant configurations using the files under the DesignConfig classification. Model variant configurations include:

  • Power Window Controller Hybrid System Model

  • Power Window Controller and Detailed Plant Model

  • Power Window Controller With Data Acquisition Effects

  • Power Window Controller With Controller Area Network (CAN) Communication

Power Window Controller Hybrid System Model

This model variant uses Stateflow® and Simulink to model both discrete event reactive behavior and continuous time behavior. The models uses a low-order plant model to validate the roll-up and roll-down behavior. You can simulate this variant configuration using the SimHybridPlantLowOrder shortcut. This shortcut activates only the variant subsystem corresponding to this model configuration. Since this model does not take into account power effects, the only output logged is position. The Simulation Data Inspector displays the logged position data.

Power Window Controller and Detailed Plant Model

This model variant shows a more detailed plant model that includes power effects in the electrical and mechanical domains. This variant validates that the force exerted by the window on a trapped object never exceeds 100 N. This model variant requires Simscape™ Multibody™ and Simscape™ Electrical™ licenses. You can simulate this variant configuration using the SimHybridPlantPowerEffects shortcut. Unlike the Power Window Controller Hybrid System Model, this variant configuration takes into account the power effects. The Simulation Data Inspector displays the logged data from armature current, position, and force exerted by the power window.

Power Window Controller With Data Acquisition Effects

This model variant shows additional effects due to implementation that affect the control. The phenomena included are signal conditioning to measure the armature current and quantization of the measurement. This model variant requires Simscape Multibody, Simscape Electrical, DSP System Toolbox™, and Fixed-Point Designer™ licenses. You can simulate this variant configuration using the SimHybridPlantPowerEffects+ControlDAQEffects shortcut. As with the Power Window Controller and Detailed Plant Model, the Simulation Data Inspector displays the logged data from armature current, position, and force exerted by the power window.

Power Window Controller With CAN Communication

This model variant shows the use of a CAN to communicate the commands to control window movement. The switches that may be located in the center console of the vehicle and that produce the commands are included in this model variant. This model variant requires Simscape Multibody, Simscape Electrical, DSP System Toolbox, and Fixed-Point Designer licenses. You can simulate this variant configuration on a machine running windows OS using the SimCANCommunication shortcut.

Models for Testing

To test the state machine that controls the power window, you can run the project shortcuts for testing. Model shortcuts for testing the controller include:

  • InteractiveExample

  • CoverageExample

  • IncreaseCoverageExample

InteractiveExample

This model shortcut opens the model slexPowerWindowCntlInteract. This model contains the power window controller, which is a state machine. This model also contains inputs to the controller that are selected with manual switch blocks.

The power window controller has four external inputs:

Passenger Input input consists of a vector with three elements:

  • neutral: Passenger control switch is not depressed.

  • up: Passenger control switch generates the up signal.

  • down: Passenger control switch generates the down signal.

Driver Input input consists of a vector with three elements:

  • neutral: Driver control switch is not depressed.

  • up: Driver control switch generates the up signal.

  • down: Driver control switch generates the down signal.

Window Frame Endstops input consists of a vector with two elements:

  • 0: Window moves freely between top or bottom.

  • 1: Window is stuck at the top or bottom because of physical limitations.

Obstacle Present input consists of a vector with two elements:

  • 0: window moves freely between top or bottom

  • 1: window has obstacle within its frame

You can interactively test the controller by simulating the model and selecting the desired combination of inputs via the manual switch blocks. After selecting inputs, you can verify the internal controller state and controller output against the desired result for the specific set of inputs.

CoverageExample

This model shortcut opens the model slexPowerWindowCntlCoverage. The model contains a state machine power window controller with Repeating Sequence block inputs.

You can use the Simulink Coverage Model Coverage tool to validate the discrete event control of the window. The Model Coverage tool determines the extent to which a model test case exercises the conditional branches of the controller. The tool evaluates whether all transitions in the discrete event control are taken given the test case. The tool also evaluates whether all clauses in a condition that enables a particular transition have become true. One transition may be enabled by multiple clauses, for example, the transition from emergency back to neutral occurs when either 100 ticks have occurred or when the endstop is reached.

IncreaseCoverageExample

This model shortcut opens the model slexPowerWindowCntlCoverageIncrease. This model contains the power window controller that is a state machine. This model also contains a From Spreadsheet block that provides multiple sets of inputs to the controller. These input sets combine with the one from the CoverageExample model to exercise more of the logic in the power window controller:

  • Logged: Logged from the CoverageExample.

  • LoggedObstacleOffEndStopOn: Logged from the CoverageExample with ability to hit endstop.

  • LoggedObstacleOnEndStopOff: Logged from the CoverageExample with obstacle in window.

  • LoggedObstacleOnEndStopOn: Logged from the CoverageExample with obstacle in window and ability to hit endstop.

  • DriverLoggedPassengerNeutral: Logged from the CoverageExample for only the driver. Passenger takes no action.

  • DriverDownPassengerNeutral: Driver lowering window. Passenger takes no action.

  • DriverUpPassengerNeutral: Driver raising window. Passenger takes no action.

  • DriverAutoDownPassengerNeutral: Driver lowering window for 1 second (auto-down). Passenger takes no action.

  • DriverAutoUpPassengerNeutral: Driver raising window for 1 second (auto-up). Passenger takes no action.

  • PassengerAutoDownDriverNeutral: Passenger lowering window for 1 second (auto-down). Driver takes no action.

  • PassengerAutoUpDriverNeutral: Passenger raising window for 1 second (auto-up). Driver takes no action.

The model coverage shortcut GenerateIncreasedCoverage uses the multiple input sets with the Simulink Coverage Model Coverage tool to validate the discrete event control of the window and generate a coverage report for the multiple input sets.

Quantitative Requirements

Quantitative requirements for the control are:

  • The window must fully open and fully close within 4 s.

  • If the up is issued for between 200 ms and 1 s, the window must fully open. If the down command is issued for between 200 ms and 1 s, the window must fully close.

  • The window must start moving 200 ms after the command is issued.

  • The force to detect when an object is present is less than 100 N.

  • When closing the window, if an object is in the way, stop closing the window and lower the window by approximately 10 cm.

Capturing Requirements in Activity and Context Diagrams

Activity diagrams help you graphically capture the specification and understand how the system operates. A hierarchical structure helps with analyzing even large systems. At the top level, a context diagram describes the system environment and its interaction with the system under study in terms of data exchange and control operations. Then you can decompose the system into an activity diagram with processes and control specifications (CSPEC).

The processes guide the hierarchical decomposition. You specify each process using another activity diagram or a primitive specification (PSPEC). You can specify a PSPEC in a number of representations with a formal semantic, such as a Simulink block diagram. In addition, context diagrams graphically capture the context of system operation. Use the data definitions for the specifications.

Context Diagram: Power Window System

The figure represents the context diagram of a power window system. The square boxes capture the environment, in this case, the driver, passenger, and window. Both the driver and passenger can send commands to the window to move it up and down. The controller infers the correct command to send to the window actuator (e.g., the driver command has priority over the passenger command). In addition, diagram monitors the state of the window system to establish when the window is fully opened and closed and to detect if there is an object between the window and frame.

The circle (also known as a bubble) represents the power window controller. The circle is the graphical notation for a process. Processes capture the transformation of input data into output data. Primitive process might also generate. CSPECs typically consist of combinational or sequential logic to infer output control signals from input control.

For implementation in the Simulink environment, see Implement Context Diagram: Power Window System.

Power Window System Data Definitions

SignalInformation TypeContinuous/
Discrete
Data TypeValues

DRIVER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

PASSENGER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

WINDOW_POSITION

Data

Continuous

Real

0 to 0.4 m

MOVE_UP

Control

Discrete

Boolean

'True', 'False'

MOVE_DOWN

Control

Discrete

Boolean

'True', 'False'

Activity Diagram: Power Window Control

The power window control consists of three processes and a CSPEC. Two processes validate the driver and passenger input to ensure that their input is meaningful given the state of the system. For example, if the window is completely opened, the MOVE DOWN command does not make sense. The remaining process detects if the window is completely opened or completely closed and if an object is present. The CSPEC takes the control signals and infers whether to move the window up or down (e.g., if an object is present, the window moves down for about one second or until it reaches an endstop).

Power Window Control Data Definitions

SignalInformation TypeContinuous/
Discrete
Data TypeValues

DRIVER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

PASSENGER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

WINDOW_POSITION

Data

Continuous

Real

0 to 0.4 m

MOVE_UP

Control

Discrete

Boolean

'True', 'False'

MOVE_DOWN

Control

Discrete

Boolean

'True', 'False'

Activity Diagram: Validate Driver

Each process in the VALIDATE DRIVER activity chart is primitive and specified by the following PSPEC. In the MAKE EXCLUSIVE PSPEC, for safety reasons the DOWN command takes precedence over the UP command.

PSPEC 1.1.1: CHECK DOWN
  CHECKED_DOWN = DOWN and not RESET
PSPEC 1.1.2: CHECK UP
  CHECKED_UP = UP and not RESET
PSPEC 1.1.3: MAKE EXCLUSIVE
  VALIDATED_DOWN    = CHECKED_DOWN
  VALIDATED_UP      = CHECKED_UP and not CHECKED_DOWN
  VALIDATED_NEUTRAL = (NEUTRAL and not (CHECKED_UP and not CHECKED_DOWN))
                        or not (CHECKED_UP or CHECKED_DOWN)

Validate Driver Data Definitions

SignalInformation TypeContinuous/
Discrete
Data TypeValues

DRIVER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

PASSENGER_COMMAND

Data

Discrete

Aggregate

Neutral, up, down

WINDOW_POSITION

Data

Continuous

Real

0 to 0.4 m

MOVE_UP

Control

Discrete

Boolean

'True', 'False'

MOVE_DOWN

Control

Discrete

Boolean

'True', 'False'

Activity Diagram: Validate Passenger

The internals of the VALIDATE PASSENGER process are the same as the VALIDATE DRIVER process. The only difference is the different input and output.

PSPEC 1.2.1: CHECK DOWN
  CHECKED_DOWN = DOWN and not RESET
PSPEC 1.2.2: CHECK UP
  CHECKED_UP = UP and not RESET
PSPEC 1.2.3: MAKE EXCLUSIVE
  VALIDATED_DOWN    =  CHECKED_DOWN
  VALIDATED_UP      =  CHECKED_UP and not CHECKED_DOWN
  VALIDATED_NEUTRAL = (NEUTRAL and not (CHECKED_UP and not CHECKED_DOWN))
                        or not (CHECKED_UP or CHECKED_DOWN)

For implementation in the Simulink environment, see Activity Diagram: Validate Passenger.

Validate Passenger Data Definitions

SignalInformation TypeContinuous/
Discrete
Data TypeValues

NEUTRAL

Data

Discrete

Boolean

'True', 'False'

UP

Data

Discrete

Boolean

'True', 'False'

DOWN

Data

Discrete

Boolean

'True', 'False'

CHECKED_UP

Data

Discrete

Boolean

'True', 'False'

CHECKED_DOWN

Data

Discrete

Boolean

'True', 'False'

Activity Diagram: Detect Obstacle Endstop

The third process in the POWER WINDOW CONTROL activity diagram detects the presence of an obstacle or when the window reaches its top or bottom (ENDSTOP). The detection mechanism is based on the armature current of the window actuator. During normal operation, this current is within certain bounds. When the window reaches its top or bottom, the electromotor draws a large current (more than 15 A or less than –15 A) to try and sustain its angular velocity. Similarly, during normal operation the current is about 2 A or –2 A (depending on whether the window is opening or closing). When there is an object, there is a slight deviation from this value. To keep the window force on the object less than 100 N, the control switches to its emergency operation when it detects a current that is less than –2.5 A. This operations is necessary only when the window is rolling up, which corresponds to a negative current in the particular wiring of this model. The DETECT OBSTACLE ENDSTOP activity diagram embodies this functionality.

CSPEC 1.3: DETECT OBSTACLE ENDSTOP
  RESET = OBSTACLE or ENDSTOP
PSPEC 1.3.1: DETECT ENDSTOP
  ENDSTOP = WINDOW_POSITION > ENDSTOP_MAX
PSPEC 1.3.2: DETECT OBSTACLE
  OBSTACLE = (WINDOW_POSITION > OBSTACLE_MAX) and MOVE_UP for 500 ms

For implementation in the Simulink environment, see Activity Diagram: Detect Obstacle Endstop.

Detect Obstacle Endstop Data Definitions

SignalInformation TypeContinuous/
Discrete
Data TypeValues

ENDSTOP_MIN

Data

Constant

Real

0.0 m

ENDSTOP_MAX

Data

Constant

Real

0.4 m

OBSTACLE_MAX

Data

Constant

Real

0.3 m

Implement Activity Diagram: Power Window Control

This topic describes the high-level discrete-event control specification for a power window control.

You can model the discrete-event control of the window with a Stateflow® chart. A Stateflow chart is a finite state machine with hierarchy and parallelism. This state machine contains the basic states of the power window system: up, auto-up, down, auto-down, rest, and emergency. It models the state transitions and accounts for the precedence of driver commands over the passenger commands. It also includes emergency behavior that activates when the software detects an object between the window and the frame while moving up.

The initial Simulink model for the power window control, slexPowerWindowControl, is a discrete-event controller that runs at a given sample rate.

In this implementation, open the power window control subsystem and observe that the Stateflow chart with the discrete-event control forms the CSPEC, represented by the tilted thick bar in the bottom right corner. The detect_obstacle_endstop subsystem encapsulate the threshold detection mechanisms.

The discrete-event control is a Stateflow model that extends the state transition diagram notion with hierarchy and parallelism. State changes because of passenger commands are encapsulated in a super state that does not correspond to an active driver command.

Consider the control of the passenger window. The passenger or driver can move this window up and down.

This state machine contains the basic states of the power window system: up, auto-up, down, auto-down, rest, and emergency.

Interactive Testing

Control Input

The slexPowerWindowCntlInteract model includes this control input as switches. Double-click these switches to manually operate them.

Test the state machine that controls a power window by running the input test vectors and checking that it reaches the desired internal state and generates output. The power window has the following external inputs:

  • Passenger input

  • Driver input

  • Window up or down

  • Obstacle in window

Each input consists of a vector with these inputs.

Passenger Input

ElementDescription
neutral

Passenger control switch is not depressed.

up

Passenger control switch generates the up signal.

down

Passenger control switch generates the down signal.

Driver Input

ElementDescription
neutral

Driver control switch is not depressed.

up

Driver control switch generates the up signal.

down

Driver control switch generates the down signal.

Window Up or Down

ElementDescription
0

Window moves freely between top or bottom.

1

Window is stuck at the top or bottom because of physical limitations.

Obstacle in Window

ElementDescription
0

Window moves freely between top or bottom.

1

Window has obstacle in the frame.

Generate the passenger and driver input signals by mapping the up and down signals according to this table:

InputsOutputs
updownupdownneutral

0

0

0

0

1

0

1

0

1

0

1

0

1

0

0

1

1

0

0

1

The inputs explicitly generate the neutral event from the up and down events, generated by pressing a power window control switch. The inputs are entered as a truth table in the passenger neutral, up, down map and the driver neutral, up, down map.

Case 1: Window Up

To observe the state machine behavior:

  1. Open the slexPowerWindowCntlInteract model.

  2. Run the simulation and then double-click the passenger up switch.

    If you press the physical window switch for more than one second, the window moves up until the up switch is released (or the top of the window frame is reached and the endstop event is generated).

  3. Double-click the selected passenger up switch to release it.

  4. Simulate the model.

    Setting the endstop switch generates the endstop event.

Case 2: Window Auto-Up

If you press the physical passenger window up switch for a short period of time (less than a second), the software activates auto-up behavior and the window continues to move up.

  1. Press the physical passenger window up switch for a short period of time (less than a second).

    Ultimately, the window reaches the top of the frame and the software generates the endstop event. This event moves the state machine back to its neutral state.

  2. Simulate the model.

Case 3: Driver-Side Precedence

The driver switch for the passenger window takes precedence over the driver commands. To observe the state machine behavior in this case:

  1. Run the simulation, and then move the system to the passenger up state by double-clicking the passenger window up switch.

  2. Double-click the driver down switch.

  3. Simulate the model.

  4. Notice how the state machine moves to the driver control part to generate the window down output instead of the window up output.

  5. Double-click the driver control to driver up. Double-click the driver down switch.

    The driver window up state is reached, which generates the window up output again, i.e., windowUp = 1.

  6. To observe state behavior when an object is between the window and the frame, double-click the obstacle switch.

  7. Simulate the model.

    On the next sample time, the state machine moves to its emergencyDown state to lower the window a few inches. How far the software lowers the window depends on how long the state machine is in the emergencyDown state. This behavior is part of the next analysis phase.

    If a driver or passenger window switch is still active, the state machine moves into the up or down states upon the next sample time after leaving the emergency state. If the obstacle switch is also still active, the software again activates the emergency state at the next sample time.

Model Coverage

Validation of the Control Subsystem

Validate the discrete-event control of the window using the model coverage tool. This tool helps you determine the extent to which a model test case exercises the conditional branches of the controller. It helps evaluate whether all transitions in the discrete-event control are taken, given the test case, and whether all clauses in a condition that enables a particular transition have become true. Multiple clauses can enable one transition, e.g., the transition from emergency back to neutral occurs when either 100 ticks have occurred or if the endstop is reached.

To achieve full coverage, each clause evaluates to true and false for the test cases used. The percentage of transitions that a test case exercises is called its model coverage. Model coverage is a measure of how thoroughly a test exercises a model.

Using Simulink Coverage™ software, you can apply the following test to the power window controller.

PositionStep
0123456
Passenger up 0000000
Passenger down0001011
Driver up 0010101
Driver down0100110

With this test, all switches are inactive at time 0. At regular 1 s steps, the state of one or more switches changes. For example, after 1 s, the driver down switch becomes active. To automatically run these input vectors, replace the manual switches by prescribed sequences of input. To see the preconstructed model:

  1. Open the slexPowerWindowCntlCoverage model.

  2. Simulate the model to generate the Simulink Coverage coverage report.

For the slexPowerWindowCntlCoverage model, the report reveals that this test handles 100% of the decision outcomes from the driver neutral, up, down map block. However, the test achieves only 50% coverage for the passenger neutral, up, down map block. This coverage means the overall coverage for slexPowerWindowCntlCoverage is 45% while the overall coverage for the slexPowerWindowControl model is 42%. A few of the contributing factors for the coverage levels are:

  • Passenger up block does not change.

  • Endstop and obstacle blocks do not change.

Increase Model Coverage

To increase total coverage to 100%, you need to take into account all possible combinations of driver, passenger, obstacle, and endstop settings. When you are satisfied with the control behavior, you can create the power window system. For more information, see Create Model Using Model-Based Design.

This example increases the model coverage for the validation of the discrete-event control of the window. To start, the example uses inputs from slexPowerWindowCntlCoverage as a baseline for the model coverage. Next, to further exercise the discrete-event control of the window, it creates more input sets. The spreadsheet file, inputCntlCoverageIncrease.xlsx, contains these input sets using one input set per sheet.

In the example, the slexPowerWindowSpreadsheetGeneration utility function, which creates a spreadsheet template from the controller model, slexPowerWindowControl, creates the inputCntlCoverageIncrease.xlsx. In inputCntlCoverageIncrease.xlsx, the function uses the block names in the controller model as signal names. slexPowerWindowSpreadsheetGeneration defines the sheet names. The slexWindowSpreadsheetAddInput utility function populates inputCntlCoverageIncrease.xlsx with signal data.

The sheet names of these input sets and their descriptions are:

Sheet NameDescription

Logged

Inputs logged from slexPowerWindowCntlCoverage

LoggedObstacleOffEndStopOn

Inputs logged from slexPowerWindowCntlCoverage with ability to hit endstop

LoggedObstacleOnEndStopOff

Inputs logged from slexPowerWindowCntlCoverage with obstacle in window

LoggedObstacleOnEndStopOn

Inputs logged from slexPowerWindowCntlCoverage with obstacle in window and ability to hit endstop

DriverLoggedPassengerNeutral

Inputs logged from slexPowerWindowCntlCoverage for driver only and passenger takes no action

DriverDownPassengerNeutral

Driver is putting down window and passenger takes no action

DriverUpPassengerNeutral

Driver is putting up window and passenger takes no action

DriverAutoDownPassengerNeutral

Driver is putting down window for one second (auto-down) and passenger takes no action

DriverAutoUpPassengerNeutral

Driver is putting up window for one second (auto-up) and passenger takes no action

PassengerAutoDownDriverNeutral

Passenger is putting down window for one second (auto-down) and driver takes no action

PassengerAutoUpDriverNeutral

Passenger is putting up window for one second (auto-up) and driver takes no action

To automatically run these input vectors, replace the inputs to the discrete-event control with the From Spreadsheet block using the file, inputCntlCoverageIncrease.xlsx. This file contains the multiple input sets. To see the preconstructed model:

  1. Open the slexPowerWindowCntlCoverageIncrease model.

  2. To generate the Simulink Coverage coverage report for multiple input set, double click the Run Coverage subsystem in the model.

    For the slexPowerWindowCntlCoverageIncrease model, the report reveals that using multiple input sets has successfully raised the overall coverage for the slexPowerWindowControl model from 42% to 78%. Coverage levels are less than 100% because of missing input sets for:

    • Passenger up state

    • Driver up and down states

    • Passenger automatic down and automatic up states

Create Model Using Model-Based Design

Implement Context Diagram: Power Window System

For requirements presented as a context diagram, see Context Diagram: Power Window System.

Create a Simulink model to resemble the context diagram.

  1. Place the plant behavior into one subsystem.

  2. Create two subsystems that contain the driver and passenger switches.

  3. Add a control mechanism to conveniently switch between the presence and absence of the object.

  4. Put the control in one subsystem.

  5. Connect the new subsystems.

  6. To see an implementation of this model, open the slexPowerWindowExample model.

You can use the power window control activity diagram (Activity Diagram: Power Window Control) to decompose the power window controller of the context diagram into parts. This diagram shows the input and output signals present in the context diagram for easier tracing to their origins.

Implement Power Window Control System

To satisfy full requirements, the power window control must work with the validation of the driver and passenger inputs and detect the endstop.

For requirements presented as an activity diagram, see Activity Diagram: Power Window Control.

Double-click the slexPowerWindowExample/power_window_control_system block to open the following subsystem:

Implement Activity Diagram: Validate

For requirements presented as activity diagrams, see Activity Diagram: Validate Driver and Activity Diagram: Validate Passenger.

The activity diagram adds data validation functionality for the driver and passenger commands to ensure correct operation. For example, when the window reaches the top, the software blocks the up command. The implementation decomposes each validation process in new subsystems. Consider the validation of the driver commands (validation of the passenger commands is similar). Check if the model can execute the up or down commands, according to the following:

  • The model allows the down command only when the window is not completely opened.

  • The model allows the up command only when the window is not completely closed and no object is detected.

The third activity diagram process checks that the software sends only one of the three commands (neutral, up, down) to the controller. In an actual implementation, both up and down can be simultaneously true (for example, because of switch bouncing effects).

From the power_window_control_system subsystem, this is the validate_driver_state subsystem:

From the power_window_control_system subsystem, this is the validate_passenger_state subsystem:

Implement Activity Diagram: Detect Obstacle Endstop

For requirements presented as an activity diagram, see Activity Diagram: Detect Obstacle Endstop.

In the slexPowerWindowExample model, the power_window_control_system/detect_obstacle_endstop block implements this activity diagram in the continuous variant of the Variant Subsystem block. During design iterations, you can add additional variants.

Double-click the slexPowerWindowExample model power_window_control_system/detect_obstacle_endstop/Continuous/verify_position block.

Hybrid Dynamic System: Combine Discrete-Event Control and Continuous Plant

After you have designed and verified the discrete-event control, integrate it with the continuous-time plant behavior. This step is the first iteration of the design with the simplest version of the plant.

In the project, navigate to Files and click Project. In the configureModel folder, run the slexPowerWindowContinuous utility to open and initialize the model.

The window_system block uses the Variant Subsystem block to allow for varying levels of fidelity in the plant modeling. Double-click the window_system/Continuous/2nd_order_window_system block to see the continuous variant.

The plant is modeled as a second-order differential equation with step-wise changes in its input:

  • When the Stateflow chart generates windowUp, the input is 1.

  • When the Stateflow chart generates windowDown, the input is –1.

  • Otherwise, the input is 0.

This phase allows analysis of the interaction between the discrete-event state behavior, its sample rate, and the continuous behavior of the window movement. There are threshold values to generate the window frame top and bottom:

  • endStop

  • Event when an obstacle is present, that is, obstacle

  • Other events

Double-click the slexPowerWindowExample model power_window_control_system/detect_obstacle_endstop/Continuous/verify_position block to see the continuous variant.

When you run the slexPowerWindowContinuous configureModel utility, the model uses the continuous time solver ode23 (Bogacki-Shampine).

A structure analysis of a system results in:

  • A functional decomposition of the system

  • Data definitions with the specifics of the system signals

  • Timing constraints

A structure analysis can also include the implementation architecture (outside the scope of this discussion).

The implementation also adds a control mechanism to conveniently switch between the presence and absence of the object.

Expected Controller Response.  To view the window movement, in Project Shortcuts, double-click SimHybridPlantLowOrder. Alternatively, you can run the task slexPowerWindowContinuousSim.

The position scope shows the expected result from the controller. After 30 cm, the model generates the obstacle event and the Stateflow chart moves into its emergencyDown state. In this state, windowDown is output until the window lowers by about 10 cm. Because the passenger window up switch is still on, the window starts moving up again and this process repeats. Stop the simulation and open the position scope to observe the oscillating process. In case of an emergency, the discrete-event control rolls down the window approximately 10 cm.

Detailed Modeling of Power Effects

After an initial analysis of the discrete-event control and continuous dynamics, you can use a detailed plant model to evaluate performance in a more realistic situation. It is best to design models at such a level of detail in the power domain, in other words, as energy flows. Several domain-specific MathWorks blocksets can help with this.

To take into account energy flows, add a more detailed variant consisting of power electronics and a multibody system to the window_system variant subsystem.

To open the model and explore the more detailed plant variant, in the project, run configureModel slexPowerWindowPowerEffects.

Double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system block.

Power Electronics Subsystem.  The model must amplify the control signals generated by the discrete-event controller to be powerful enough to drive the DC motor that moves the window.

The amplification modules model this behavior. They show that a switch either connects the DC motor to the battery voltage or ground. By connecting the battery in reverse, the system generates a negative voltage and the window can move up, down, or remain still. The window is always driven at maximum power. In other words, no DC motor controller applies a prescribed velocity.

To see the implementation, double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system/amplification_up block.

Multibody System.  This implementation models the window using Simscape™ Multibody™ blocks.

To see the actuator implementation, double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system/actuator block.

To see the window implementation, double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system/plant block.

This implementation uses Simscape Multibody blocks for bodies, joints, and actuators. The window model consists of:

  • A worm gear

  • A lever to move the window holder in the vertical direction

The figure shows how the mechanical parts move.

Iterate on the Design.  An important effect of the more detailed implementation is that there is no window position measurement available. Instead, the model measures the DC motor current and uses it to detect the endstops and to see if an obstacle is present. The next stage of the system design analyzes the control to make sure that it does not cause excessive force when an obstacle is present.

In the original system, the design removes the obstacle and endstop detection based on the window position and replaces it with a current-based implementation. It also connects the process to the controller and position and force measurements. To reflect the different signals used, you must modify the data definition. In addition, observe that, because of power effects, the units are now amps.

PSPEC 1.3.1: DETECT ENDSTOP
  ENDSTOP = ARMATURE_CURRENT > ENDSTOP_MAX
PSPEC 1.3.2: DETECT OBSTACLE
  OBSTACLE = (ARMATURE_CURRENT > OBSTACLE_MAX) and MOVE_UP for 500 ms
PSPEC 1.3.3: ABSOLUTE VALUE
  ABSOLUTE_ARMATURE_CURRENT = abs(ARMATURE_CURRENT)

This table lists the additional signal for the Context Diagram: Power Window System data definitions.

Context Diagram: Power Window System Data Definition Changes

SignalInformation TypeContinuous/
Discrete
Data TypeValues

ARMATURE_CURRENT

Data

Continuous

Real

–20 to 20 A

This table lists the changed signals for the Activity Diagram: Detect Obstacle Endstop data definitions.

Activity Diagram: Detect Obstacle Endstop Data Definition Changes

SignalInformation TypeContinuous/
Constant
Data TypeValues

ABSOLUTE_ARMATURE_CURRENT

Data

Continuous

Real

0 to 20 A

ENDSTOP_MAX

Data

Constant

Real

15 A

OBSTACLE_MAX

Data

Constant

Real

2.5 A

To see the window subsystem, double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system/plant/window block.

The implementation uses a lookup table and adds noise to allow evaluation of the control robustness. To see the implementation of the friction subsystem, double-click the slexPowerWindowExample model window_system/Power Effects - Visualization/detailed_window_system/plant/window/friction block.

Control Law Evaluation

The idealized continuous plant allows access to the window position for endStop and obstacle event generation. In the more realistic implementation, the model must generate these events from accessible physical variables. For power window systems, this physical variable is typically the armature current, Ia, of the DC motor that drives the worm gear.

When the window is moving, this current has an approximate value of 2 A. When you switch the window on, the model draws a transient current that can reach a value of approximately 10 A. When the current exceeds 15 A, the model activates endstop detection. The model draws this current when the angular velocity of the motor is kept at almost 0 despite a positive or negative input voltage.

Detecting the presence of an object is more difficult in this setup. Because safety concerns restrict the window force to no more than 100 N, an armature current much less than 10 A should detect an object. However, this behavior conflicts with the transient values achieved during normal operation.

Implement a control law that disables object detection during achieved transient values. Now, when the system detects an armature current more than 2 A, it considers an object to be present and enters the emergencyDown state of the discrete-event control. Open the force scope window (measurements are in newtons) to check that the force exerted remains less than 100 N when an object is present and the window reverses its velocity.

In reality, far more sophisticated control laws are possible and implemented. For example, you can implement neural-network-based learning feedforward control techniques to emulate the friction characteristic of each individual vehicle and changes over time.

Visualization of the System in Motion

If you have Simulink 3D Animation™ software installed, you can view the geometrics of the system in motion via a virtual reality world. If the VR Sink block is not yet open, in the slexPowerWindowExample/window_world/Simulink_3D_Animation View model, double-click the VR Sink block.

To simulate the model with a stiff solver:

  1. In a project, run the task, slexPowerWindowPowerEffectsSim. This batch job sets the solver to ode23tb (stiff/TR-BDF2).

  2. In the slexPowerWindowExample model passenger_switch/Normal block, set the passenger up switch to on.

  3. In the slexPowerWindowExample model driver_switch/Normal block, set the driver up switch to off.

  4. Simulate the model.

  5. Between 10 ms and 1 s in simulation time, switch off the slexPowerWindowExample/passenger_switch/Normal block passenger up switch to initiate the auto-up behavior.

  6. Observe how the window holder starts to move vertically to close the window. When the model encounters the object, it rolls the window down.

  7. Double-click the slexPowerWindowExample model passenger_switch/Normal block driver down switch to roll down the window completely and then simulate the model. In this block, at less than one second simulation time, switch off the driver down switch to initiate the auto-down behavior.

  8. When the window reaches the bottom of the frame, stop the simulation.

  9. Look at the position measurement (in meters) and at the armature current (Ia) measurement (in amps).

    Note

    The absolute value of the armature current transient during normal behavior does not exceed 10 A. The model detects the obstacle when the absolute value of the armature current required to move the window up exceeds 2.5 A (in fact, it is less than –2.5 A). During normal operation, this is about 2 A. You might have to zoom into the scope to see this measurement. The model detects the window endstop when the absolute value of the armature current exceeds 15 A.

    Variation in the armature current during normal operation is due to friction that is included by sensing joint velocities and positions and applying window specific coefficients.

Realistic Armature Measurement

The armature current as used in the power window control is an ideal value that is accessible because of the use of an actuator model. In a more realistic situation, data acquisition components must measure this current value.

To include data acquisition components, add the more realistic measurement variant to the window_system variant subsystem. This realistic measurement variant contains a signal conditioning block in which the current is derived based on a voltage measurement.

To open a model and configure the realistic measurement, in the project, run the configureModel task slexPowerWindowRealisticArmature.

To view the contents of the Realistic Armature - Communications Protocol block, double-click the SlexPowerWindowExample model window_system/Realistic Armature - Communications Protocol/detailed_window_system_with_DAQ.

The measurement voltage is within the range of an analog-to-digital converter (ADC) that discretizes based on a given number of bits. You must scale the resulting value based on the value of the resistor and the range of the ADC.

Include these operations as fixed-point computations. To achieve the necessary resolution with the given range, 16 bits are required instead of 8.

Study the same scenario:

  1. In the slexPowerWindowExample/passenger_switch/Normal block, set the passenger up switch.

  2. Run the simulation.

  3. After some time, in the slexPowerWindowExample/passenger_switch/Normal block, switch off the passenger up switch.

  4. When the window has been rolled down, click the slexPowerWindowExample/passenger_switch/Normal block driver down switch.

  5. After some time, switch off the slexPowerWindowExample/passenger_switch/Normal block driver down switch.

  6. When the window reaches the bottom of the frame, stop the simulation.

  7. Zoom into the armature_current scope window and notice the discretized appearance.

Communication Protocols

Similar to the power window output control, hardware must generate the input events. In this case, the hardware is the window control switches in the door and center control panels. Local processors generate these events and then communicate them to the window controller via a CAN bus.

To include these events, add a variant containing input from a CAN bus and switch components that generate the events delivered on the CAN bus to the driver switch and passenger switch variant subsystems. To open the model and configure the CAN communication protocols, run the configureModel task, slexPowerWindowCommunicationProtocolSim.

To see the implementation of the switch subsystem, double-click the slexPowerWindowExample/driver_switch/Communication Protocol/driver window control switch block.

Observe a structure that is very similar to the window control system. This structure contains a:

  • Plant model that represents the control switch

  • Data acquisition subsystem that includes, among other things, signal conditioning components

  • Control module to map the commands from the physical switch to logical commands

  • CAN module to post the events to the vehicle data bus

You can add communication effects, such as other systems using the CAN bus, and more realism similar to the described phases. Each phase allows analysis of the discrete-event controller in an increasingly realistic situation. When you have enough detail, you can automatically generate controller code for any specific target platform.

Automatic Code Generation for Control Subsystem

You can generate code for the designed control model, slexPowerWindowExample.

  1. Display the sample rates of the controller. In the Simulink Editor, on the Debug tab, select Information Overlays > Sample Time > Colors. Observe that the controller runs at a uniform sample rate.

  2. Right-click the power_window_control_system block and select C/C++ Code > Build This Subsystem.

References

Mosterman, Pieter J., Janos Sztipanovits, and Sebastian Engell, “Computer-Automated Multiparadigm Modeling in Control Systems Technology,” IEEE Transactions on Control Systems Technology, Vol. 12, Number 2, 2004, pp. 223–234.

Related Examples

More About